Abstract
This paper presents a rapid seismic assessment and Fibre Reinforced Polymer (FRP) retrofit design methodology which relies on the European design guidelines recently published in Chapter 8 of fib Bulletin 90 on the use of externally applied FRP reinforcement in the seismic retrofitting of reinforced concrete (r.c.) structures. For this purpose, an example-guide is developed with step-by-step hand calculations aiming to facilitate engineers of practice and researchers working in the field to easily understand the proposed methodology. A three-storey, pilotis-type residential r.c. building is selected typical of the Mediterranean construction practice in the 1970s. The methodology followed only aims to provide preliminary results on seismic assessment and retrofitting before the implementation of more sophisticated analysis if need be (e.g., in case of irregular buildings). The assessment procedure identified that the columns of the ground storey, being the most critical structural elements for the stability of the structure, are vulnerable to brittle failure modes. To remove all the brittle failure modes attributed to inherent deficiencies and enhance the overall deformation capacity of the building, the strengthening schemes applied in the ground storey (pilotis) is a combination of local strengthening measures, such as FRP wrapping, and global interventions. The latter may refer to the addition of r.c. jacketing to the central column to remove slenderness and of metal X-braces to modify the lateral deflection shape of the building and thus moderate the interstorey displacement demand.
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Reference36 articles.
1. Fib Bulletin 14 (2001). Externally Bonded FRP Reinforcement for r.c. Structures, Fédération Internationale du Béton (fib). Report by Task Group 9.3.
2. Analytical-mechanical based framework for seismic overall fragility analysis of existing RC buildings in town compartments;Ruggieri;Bull. Earthq. Eng.,2022
3. Appraising seismic vulnerability of masonry aggregates through an automated mechanical-typological approach;Leggeri;Autom. Constr.,2021
4. fib Bulletin 90 (2019). Externally Applied FRP Reinforcement for Concrete Structures, Fédération Internationale du Béton (fib). Technical Report, Task Group 5.1.
5. Background to European seismic design provisions for the retrofit of R.C. elements using FRP materials;Pantazopoulou;Fib Struct. Concr.,2015
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献