Dynamic and Steady-State Simulation Study for the Stabilization of Natural Gas Condensate and CO2 Removal through Heating and Pressure Reduction

Author:

Ehsan Mohsin12,Ali Usman1ORCID,Sher Farooq3ORCID,Abubakar Hafiz M.2,Basit Muhammad Fazal Ul4

Affiliation:

1. Department of Chemical Engineering, University of Engineering and Technology, Lahore 54890, Pakistan

2. Process Systems, Technomak Energy International FZC, Sharjah P.O. Box 41980, United Arab Emirates

3. Department of Engineering, Nottingham Trent University, Nottingham NG11 8NS, UK

4. Process Design, AIN Engineering Services, Lahore 54800, Pakistan

Abstract

Stabilization of condensate is a highly energy-consuming process compared to other oil and gas processes. There is a need to reduce this energy consumption. Therefore, the present work aims to simulate the stabilization unit in terms of available energy and on-spec stabilized condensate products. Natural gas condensate liquids (NGL) need to be stabilized by eliminating lighter hydrocarbon gases and acid gases before being sent to the refinery. Stabilized NGL has the vapor pressure determined as a Reid vapor pressure of 7 psia, showing that light components did not evolve as a separate gas phase. Stabilization and CO2 removal was performed through the distillation method by heating and pressure reduction using steady state and dynamic simulation through Aspen HYSYS. Different process alterations around the exchanger and column have been studied based on the utilities available for the stabilization and CO2 removal process. Sensitivity studies, including the impact of CO2 concentration, the temperature at the inlet of the stabilizer flash separator, and the dynamic simulation for the PID controller, have been performed to analyze the impact on the process parameters, such as Reid vapor pressure (RVP) and CO2 of the rundown air cooler and heat duties of the exchangers. Actual plant data have been used for the validation of process simulation values for the accuracy of the condensate stabilization unit model. Based on the scenarios analyzed, it can be concluded that the nitrogen stripping method achieved 7 ppmv CO2 and 7 psia RVP in the condensate from the cooler outlet, while a variation of 29 bpd was observed for the stabilized condensate flowrate throughout all scenarios with data validation showing 0.24% discrepancy between Aspen Hysys data and actual plant data.

Funder

Department of Chemical Engineering

Publisher

MDPI AG

Subject

General Energy,General Engineering,General Chemical Engineering