Effect of Digitalis on ICD or CRT-D Recipients: A Systematic Review and Meta-Analysis

Author:

Zhuo Wen1ORCID,Liu Hualong1,Fu Linghua1,Fan Weiguo1,Hong Kui123

Affiliation:

1. Department of Cardiovascular Medicine, The Second Affiliated Hospital of Nanchang University, Nanchang 330006, China

2. Jiangxi Key Laboratory of Molecular Medicine, Nanchang 330006, China

3. Department of Genetic Medicine, The Second Affiliated Hospital of Nanchang University, Nanchang 330006, China

Abstract

Background: Digitalis has been widely utilized for heart failure therapy and several studies have demonstrated an association of digitalis and adverse outcome events in patients receiving implantable cardioverter defibrillators (ICDs) or cardiac resynchronization therapy defibrillators (CRT-Ds). Hence, we conducted this meta-analysis to assess the effect of digitalis on ICD or CRT-D recipients. Methods: We systematically retrieved relevant studies using the Cochrane Library, PubMed, and Embase database. A random effect model was used to pool the effect estimates (hazard ratios (HRs) and 95% confidence intervals (CIs)) when the studies were of high heterogeneity, otherwise a fixed effect model was used. Results: Twenty-one articles containing 44,761 ICD or CRT-D recipients were included. Digitalis was associated with an increased rate of appropriate shocks (HR = 1.65, 95% CI: 1.46–1.86, p < 0.001) and a shortened time to first appropriate shock (HR = 1.76, 95% CI: 1.17–2.65, p = 0.007) in ICD or CRT-D recipients. Furthermore, the all-cause mortality increased in ICD recipients with digitalis therapy (HR = 1.70, 95% CI: 1.34–2.16, p < 0.01), but the all-cause mortality was unchanged in CRT-D recipients (HR = 1.55, 95% CI: 0.92–2.60, p = 0.10) or patients who received ICD or CRT-D therapy (HR = 1.09, 95% CI: 0.80–1.48, p = 0.20). The sensitivity analyses confirmed the robustness of the results. Conclusion: ICD recipients with digitalis therapy may tend to have higher mortality rates, but digitalis may not be associated with the mortality rate of CRT-D recipients. Further studies are required to confirm the effects of digitalis on ICD or CRT-D recipients.

Funder

National Natural Science Foundation of China

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3