A Referral Center Experience with Cerebral Protection Devices: Challenging Cardiac Thrombus in the EP Lab

Author:

Berg Jan12,Preda Alberto1,Fierro Nicolai1,Marzi Alessandra1,Radinovic Andrea1,Della Bella Paolo1,Mazzone Patrizio1

Affiliation:

1. Division of Arrhythmology, San Raffaele Hospital, 20132 Milan, Italy

2. Division of Cardiology, Cantonal Hospital of Aarau, 5001 Aarau, Switzerland

Abstract

BACKGROUND: Cerebral protection devices (CPD) are designed to prevent cardioembolic stroke and most evidence that exists relates to TAVR procedures. There are missing data on the benefits of CPD in patients that are considered high risk for stroke undergoing cardiac procedures like left atrial appendage (LAA) closure or catheter ablation of ventricular tachycardia (VT) when cardiac thrombus is present. PURPOSE: This work aimed to examine the feasibility and safety of the routine use of CPD in patients with cardiac thrombus undergoing interventions in the electrophysiology (EP) lab of a large referral center. METHODS: The CPD was placed under fluoroscopic guidance in all procedures in the beginning of the intervention. Two different CPDs were used according to the physician’s discretion: (1) a capture device consisting of two filters for the brachiocephalic and left common carotid arteries placed over a 6F sheath from a radial artery; or (2) a deflection device covering all three supra-aortic vessels placed over an 8F femoral sheath. Retrospective periprocedural and safety data were obtained from procedural reports and discharge letters. Long-term safety data were obtained by clinical follow-up in our institution and telephone consultations. RESULTS: We identified 30 consecutive patients in our EP lab who underwent interventions (21 LAA closure, 9 VT ablation) with placement of a CPD due to cardiac thrombus. Mean age was 70 ± 10 years and 73% were male, while mean LVEF was 40 ± 14%. The location of the cardiac thrombus was the LAA in all 21 patients (100%) undergoing LAA-closure, whereas, in the 9 patients undergoing VT ablation, thrombus was present in the LAA in 5 cases (56%), left ventricle (n = 3, 33%) and aortic arch (n = 1, 11%). The capture device was used in 19 out of 30 (63%) and the deflection device in 11 out of 30 cases (37%). There were no periprocedural strokes or transitory ischemic attacks (TIA). CPD-related complications comprised the vascular access and were as follows: two cases of pseudoaneurysm of the femoral artery not requiring surgery (7%), 1 hematoma at the arterial puncture site (3%) and 1 venous thrombosis (3%) resolved by warfarin. At long-term follow-up, 1 TIA and 2 non-cardiovascular deaths occurred, with a mean follow-up time of 660 days. CONCLUSIONS: Placement of a cerebral protection device prior to LAA closure or VT ablation in patients with cardiac thrombus proved feasible, but possible vascular complications needed to be taken into account. A benefit in periprocedural stroke prevention for these interventions seemed plausible but has yet to be proven in larger and randomized trials.

Publisher

MDPI AG

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3