Asymmetric Intrastromal Corneal Ring Segments with Progressive Base Width and Thickness for Keratoconus: Evaluation of Efficacy and Analysis of Epithelial Remodeling

Author:

Benlarbi Abdelmajid1,Kallel Sofiene1,David Clementine1,Barugel Raphael1,Hays Quentin1,Goemaere Isabelle1,Cuyaubere Roxane1,Borderie Marie1,Borderie Vincent12,Bouheraoua Nacim12

Affiliation:

1. CHNO des Quinze-Vingts, IHU ForeSight, INSERM-DGOS CIC 1423, 28 Rue de Charenton, F-75012 Paris, France

2. Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 Rue Moreau, F-75012 Paris, France

Abstract

Purpose: The aim of this study is to describe visual outcomes and epithelial remodeling following the implantation of asymmetric intracorneal ring segments (ICRSs) of variable thickness and base width for the management of duck-type keratoconus. Methods: A prospective observational study of patients with duck-type keratoconus was conducted. All patients received one ICRS AJL PRO + implant (AJL Ophthalmic). We analyzed demographic and clinical data, anterior segment optical coherence tomography (AS-OCT) data and Scheimpflug camera images obtained with a Placido disc MS-39 (CSO, Firenze, Italy) one and six months after surgery to determine keratometric and aberrometric outcomes and epithelial remodeling. Results: We studied 33 keratoconic eyes. ICRS implantation significantly improved both corrected distance visual acuity (CDVA) and uncorrected distance visual acuity at six months, as assessed with the logMAR (minimum angle of resolution) system, from 0.32 ± 0.19 to 0.12 ± 0.12 (p < 0.001) and from 0.75 ± 0.38 to 0.37 ± 0.24 (p < 0.001), respectively. Overall, 87% of implanted eyes gained ≥ 1 line of CDVA, and 3% of patients (n = 1) lost one line of CDVA; 55% of eyes attained a manifest refraction spherical equivalent between +1.50 and −1.50 D. Epithelial remodeling was greater at the wider and thicker end (+11.33 µm ± 12.95; p < 0.001 relative to the initial value) than at the narrower and thinner end (+2.24 µm ± 5.67; p = 0.01). Coma aberration was significantly reduced from 1.62 ± 0.81 µm to 0.99 ± 0.59 µm (p < 0.001). Conclusions: AJL-PRO + ICRS implantation for duck-type keratoconus improves refractive, topographic, aberrometric and visual parameters and induces progressive epithelial thickening along the segment.

Publisher

MDPI AG

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3