Use of Dichlorodimethylsilane to Produce Polydimethylsiloxane as a Substitute for Vitreous Humour: Characteristics and In Vitro Toxicity

Author:

Auliya Diba Grace1,Fauziah Ulfa2,Arini Vira Fuji2,Setiadji Soni3,Fitrilawati Fitrilawati2,Kartasasmita Arief Sjamsulaksan4ORCID,Risdiana Risdiana2ORCID

Affiliation:

1. Doctor Program in Biotechnology, Graduate School, Universitas Padjadjaran, Jl. Dipati Ukur No. 35, Bandung 40132, Indonesia

2. Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran, Jl. Ir. Soekarno km 21 Jatinangor, Sumedang 45363, Indonesia

3. Department of Chemistry, Faculty of Sciences and Technology, UIN Sunan Gunung Djati Bandung, Jl. A. H. Nasution No. 105 Cibiru, Bandung 40614, Indonesia

4. Department of Ophthalmology, Faculty of Medicine, Universitas Padjadjaran, Jl. Ir. Soekarno km 21 Jatinangor, Sumedang 45363, Indonesia

Abstract

Polydimethylsiloxane (PDMS) is a substitute for vitreous humour in vitreoretinal surgery and is usually produced from octamethylcyclotetrasiloxane (D4). In Indonesia, both commercial PDMS and D4 are limited and expensive. Dichlorodimethylsilane (DCMS) can be an alternative to produce PDMS. DCMS is cheaper and easier to obtain than D4. However, more extra effort is needed in order to produce PDMS from DCMS. Therefore, this study aimed to produce PDMS from DCMS by varying the ratio of DCMS precursor to dichloromethane (DCM) solvent at ratios of 1:1 and 1:4 through the hydrolysis–condensation method under neutral conditions. The PDMS produced had medium- (2.06 Pa·s) and high viscosity (3.59 Pa·s), with densities ranging from 0.96 to 0.99 g/mL. The refractive index was 1.4034–1.4036 and surface tension was 21 × 10−3 N/m, while they were able to transmit ~100% visible light, which were similar values to the commercial PDMS characteristics. PDMS samples were characterized using IR and NMR spectroscopy, which confirmed they were of PDMS type. The most optimum DCMS:DCM ratio was 1:1 due to the medium-viscosity PDMS type that could be produced. The in vitro HET–CAM toxicity test showed that samples were non-irritant, similar to PDMS produced from D4. PDMS from DCMS was non-toxic and ready to be used as a vitreous humuor substitution.

Funder

Kemenristek Indonesia

Academic Leadership Grant of Universitas Padjadjaran 2022

Publisher

MDPI AG

Subject

Biomedical Engineering,Biomaterials

Reference33 articles.

1. Thacker, M., Tseng, C.-L., and Lin, F.-H. (2021). Substitutes and Colloidal System for Vitreous Replacement and Drug Delivery: Recent Progress and Future Prospective. Polymers, 13.

2. Vitreous Substitutes: Old and New Materials in Vitreoretinal Surgery;Alovisi;J. Ophthalmol.,2017

3. The Use of Polymers in the Treatment of Retinal Detachment: Current Trends and Future Perspectives;Baino;Polymers,2010

4. Khurana, A.K. (2015). Comprehensive Ophtalmology, Jaypee Brothers Medical Publishers (P) Ltd.. [6rd, ed.].

5. Silicone Oil: Different Physical Proprieties and Clinical Applications;Barca;Bio. Med. Res. Int.,2014

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献