Abstract
This study proposes a computational design method for determining a hybrid power system’s sizing and ratio values that combines the national electric, solar cell, and fuel cell power sources. The inequality constraints associated with the ranges of power storage exchange and the stored energy are reflected as penalty functions in the overall cost function to be minimized. Using the energy hub model and the actual data for the solar cell power and the load of the residential sector in one Korean city for one hundred days, we optimize the ratio of fuel cell energy and solar cell energy to 0.46:0.54 through our proposed approach. We achieve an average cost-reduction effect of 19.35% compared to the cases in which the fuel-cell energy ratio is set from 0.1 to 0.9 in 0.1 steps. To optimize the sizing and the ratio of fuel-cell energy in the hybrid power system, we propose the modified version of the univariate dynamic encoding algorithm for searches (uDEAS) as a novel optimization method. The proposed novel approaches can be applied directly to any place to optimize an energy hub system model comprising three power sources, i.e., solar power, fuel cell, and power utility.
Funder
Ministry of Trade, Industry & Energy of KOREA
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献