Abstract
An inter-turn fault (ITF) is one of the most frequent induction motor faults; thus, many previous works have studied its model and diagnosis. However, previous works, simplifying the specific distorted flux distribution by the ITF, presented induction motor fault models and focused on the fault signal analysis for diagnoses. Consequently, these results are only adequate for the pretested motor and sensitive to fault signal distortion. This paper presents an induction motor ITF model in the stationary DQ frame, for a model-based diagnosis. Furthermore, to describe the distorted flux distribution along the air gap by the ITF, the rotor flux linkages are described in the independent DQ frame of every pole, and the mutual flux linkages among the rotor, stator, and ITF windings are specifically modeled. Hence, the proposed full model has many current states and mutual inductances to describe the high pole number motor. A simplified model is also proposed for easier usage in the diagnosis, with light ITF to overcome this complexity. Finally, simulation and experiments are performed to verify the presented induction motor ITF fault models.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献