Numerical Study of the Erosion Process and Transport of Pulverized Coal–Air Mixture in the Mill-Duct System

Author:

Hernik BartłomiejORCID

Abstract

One of the main causes of damage to the elements of coal-fired boilers installations, leading to breakdowns and, consequently, a shutdown of the block, are erosive processes. Unfortunately, there is not much research conducted on dust erosion of the dust ducts supplying the air–dust mixture to the burners. The problem of erosion of the dust ducts supplying the pulverized coal–air mixture to the burners was presented in this paper. This study was performed for the preliminary feasibility design. The destruction of the material of the dust ducts results in a failure due to erosion, resulting in the mill being shut down from an operation, which in turn may lead to the shutdown of the power plant unit. Therefore, it is important to identify places exposed to pulverized coal erosion. In order to perform calculations, numerical modeling in the commercial program Ansys.Fluent (Ansys Fluent, Computational Fluid Dynamics, Ansys Inc., Pittsburgh, PA, USA) was used. The parameters obtained as a result of laboratory tests were used in the erosion model. The places where erosion is expected are indicated. The highest erosive wear occurred for the M3 mill dust ducts for the case coal 1 and amounted to 45.6 mm/5200 h. On the other hand, the lowest erosive wear occurred for the M2 mill dust ducts powered by coal 3 and amounted to 20.9 mm/5200 h. The identification of places where erosion is expected can be used to protect these places from erosion adequately. Nevertheless, a dispersion threshold should also be placed where there is a high concentration of pulverized coal contributing to increased erosion. The numerical calculations provided information on the velocity of the medium and the behavior of the dust in the dust duct. The numerical calculations also provided information on where dust lacing has occurred. It was shown that coal dust particles with a diameter greater than 100 µm largely erode the dust duct’s wall. A model is presented for the calculation of the erosion process to be used in the dust ducts of the power plant.

Funder

Silesian University of Technology

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)

Reference43 articles.

1. Particle Impact Erosion and Abrasion Wear—Predictive Methods and Remedial Measures;Foster,2004

2. Erosion Wear in Coal Utilisation;Raask,1988

3. Зoлoвый изнoс труб и предельнo дoпустимые скoрoсти газoв в кoтельных агрегатах;Кузниецoв;Тeплoэнepгeтика,1955

4. Research on ash erosion and evaluation of boiler pipes wear as a result of its operation;Świrski,1975

5. Ash Particle Erosion on Steam Boiler Convective Section;Meuronen,1997

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3