Investigation of the Energy-Saving Potential of Buildings with Radiative Roofs and Low-E Windows in China

Author:

Jia Lin-Rui12ORCID,Li Qing-Yun3,Yang Jie4,Han Jie1,Lee Chi-Chung1ORCID,Chen Jian-Heng5

Affiliation:

1. School of Science and Technology, Hong Kong Metropolitan University, Hong Kong, China

2. Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China

3. Teaching and Learning Centre, Lingnan University, Hong Kong, China

4. Joinhuger Group Co. Ltd., Weifang 261000, China

5. School of Energy and Environment, City University of Hong Kong, Hong Kong, China

Abstract

This study develops a model for buildings with a cooling roof, walls, and low-emissivity (Low-E) windows. This model is verified through experimental analysis. The cooling demands of standard buildings and cooling buildings are compared, and the energy-saving potentials of cooling buildings are analysed. It is found that compared to standard buildings, cooling buildings exhibit superior cooling performances attributable to the application of cooling materials. Considering Hong Kong’s weather data, the indoor temperature of cooling buildings can be sub-ambient. The cooling demands of cooling buildings are decreased from 75 W/m2 to 30 W/m2, indicating a 60% energy-saving potential. The nationwide cooling demand for a standard building across China is approximately 95.7 W/m2, whereas the nationwide summer average cooling demand for cooling buildings is 52.7 W/m2. Moreover, the cooling performance of a cooling roof is adversely affected by hot and humid weather conditions, resulting in lower temperature drops in southern regions compared to northern regions. However, the nationwide temperature drop across China can still be 1.6 °C, demonstrating promising cooling potentials. For the Low-E windows, the temperature can also be sub-ambient, with a nationwide average temperature drop of 1.7 °C. Therefore, the use of Low-E windows across China can also significantly contribute to energy savings for indoor cooling. Overall, the results of this study show that cooling buildings have high energy-saving potential under various climates. The proposed model can provide a reliable tool to facilitate relevant cooling evaluation by stakeholders, thereby benefiting the popularization of this technology.

Funder

Research Grants Council of the Hong Kong Special Administrative Region, China

Publisher

MDPI AG

Subject

Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development,Building and Construction