A New Approach to Breast Specimen Orientation: Avoiding Pitfalls with the Specimen Plate Concept

Author:

Drozgyik András12ORCID,Szabó Tamás3,Kovács György4ORCID,Kollár Dániel5ORCID,Molnár Tamás F.26

Affiliation:

1. Department of Burns and Plastic Surgery, Petz Aladár University Teaching Hospital, 9024 Győr, Hungary

2. Doctoral School of Clinical Sciences, University of Pécs Medical School, 7624 Pécs, Hungary

3. Department of Pathology, Petz Aladár University Teaching Hospital, 9024 Győr, Hungary

4. Multidisciplinary Doctoral School of Engineering Sciences, Széchenyi István University, 9026 Győr, Hungary

5. Kirurgkliniken, Värnamo Sjukhus, 331 56 Värnamo, Sweden

6. Department of Operational Medicine, University of Pécs Medical School, 7624 Pécs, Hungary

Abstract

Accurate specimen marking is crucial during breast cancer surgery to avoid misorientation, which can lead to inadequate re-excision and tumor recurrence. We studied the marking methods at various breast cancer centers to create a tool that would prevent specimen misorientation. An online questionnaire was used to survey marking procedures at major breast cancer centers in Hungary, and a tool was developed using a troubleshooting method. Twelve out of twenty units responded (60%). Nine use an institutionally standardized marking system. Less than half of the surgical teams found specimen mammograms to be unambiguous. In more than 70% of departments, pathologists were uncertain about breast specimen orientation. Ambiguous marking methods caused orientation errors in half of the cases, while unclear marking directions caused the rest. Most pathologists (85%) and surgeons (75%) believed that coronal plane specimen mammography would help solve the problem. A plastic specimen plate has been developed to anchor breast tissue to a coronal breast scheme as seen in mammography images, providing clear localization information throughout the surgical process. There is a lack of standardization in breast specimen orientation and marking in Hungary. An optimized orientation toolkit is being developed to ensure consistent interpretation of specimen mammograms by surgeons and pathologists.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3