Update on Adjustable Trans-Obturator Male System (ATOMS) for Male Incontinence after Prostate Cancer Surgery

Author:

Téllez Carlos12,Szczesniewski Juliusz12ORCID,Virseda-Chamorro Miguel3,Arance Ignacio12,Angulo Javier C.12ORCID

Affiliation:

1. Clinical Department, Faculty of Biomedical Sciences, Universidad Europea, 28805 Madrid, Spain

2. Urology Department, Hospital Universitario de Getafe, 28805 Madrid, Spain

3. Urology Department, Hospital Nacional de Parapléjicos, Carretera de la Peraleda, S/N, 45004 Toledo, Spain

Abstract

(1) Background: The adjustable trans-obturator male system (ATOMS) is a surgical device developed to treat post-prostatectomy incontinence (PPI) after prostate cancer treatment. We review the current literature on this anti-incontinence device with the intention of assessing the effectiveness, safety and duration of the silicone-covered scrotal port (SSP) ATOMS, the only generation of the device that is currently available. (2) Material and Methods: Non-systematic literature review is performed. Forty-eight full-text articles are assessed for eligibility. Case reports, expert opinions or commentaries without specific data reported (n = 6), studies with patients who underwent intervention before 2014 (IP or SP ATOMS; n = 10), and studies with incontinence after transurethral resection of the prostate (TUR-P; n = 2) are excluded for analysis. Thirty studies with SSP ATOMS are included in a qualitative synthesis that incorporates systematic reviews (n = 3), articles partially overlapping with other previously published studies (e.g., follow-up or series updates; n = 9), and studies focusing on specific populations (n = 8). Only articles revealing outcomes of SSP ATOMS were included in the quantitative synthesis of results (n = 10). (3) Results: the pooled data of 1515 patients from the 10 studies with SSP ATOMS confirmed very satisfactory results with this device after adjustment: dry rate: 63–82%, improved rate: 85–100%, complication rate: 7–33%, device infection rate: 2.7–6.2% and explant rate: 0–19%. The durability of the device is reassuring, with 89% of devices in place 5 years after implantation. (4) Conclusion: Despite the absence of randomized controlled studies, the literature findings confirm results of SSP ATOMS appear equivalent to those of artificial urinary sphincters (AUSs) in terms of continence, satisfaction and complications, but with a lower rate of revision in the long-term. A prospective study identified that patients with daily pad test results <900 mL and a Male Stress Incontinence Grading Scale (MSIGS) of not 4 (i.e., early and persistent stream or urine loss) are the best candidates. Future studies centered on the elder population at higher risk of impaired cognitive ability and in patients including radiation as prostate cancer treatment are needed.

Publisher

MDPI AG

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3