Intensity Modulated and Three-Dimensional Conformal Radiation Therapy Plans for Oropharyngeal Cancer: A Comparison of Their Sensitivity to Set-Up Errors and Uncertainties

Author:

Ploquin N.,Lau H.,Dunscombe P.

Abstract

We compared the effect of set-up error and uncertainty on two radiation therapy treatment plans for head and neck cancer: one using intensity modulated radiation therapy (IMRT) and one using conventional three-dimensional conformal radiation therapy (3D-CRT). We used a Pinnacle3 (Philips Medical Systems, Markham, Ontario) system to create the two treatment plans (7-beam IMRT and 5-beam 3D-CRT) for the same volumetric data set, based on the objectives and constraints defined in the Radiation Therapy Oncology Group H-0022 protocol. In both plans, the dose–volume constraints for the targets and the organs at risk (OARS) were met as closely as the beam geometries would allow. Monte Carlo–based simulations of set-up error and uncertainty were performed in three orthogonal directions for 840 simulated “courses of treatment” for each plan. A systematic error (chosen from distributions characterized by standard deviations ranging from 0 mm to 6 mm) and random uncertainties (2 mm standard deviation) were incorporated. We used a probability approach to compare the sensitivities of the IMRT and the 3D-CRT plans to set-up error and uncertainty in terms of equivalent uniform dose (EUD) to targets and OARS. Based on the EUD analysis, the targets and OARS showed considerably greater sensitivity to set-up error with the IMRT plan than with the 3D-CRT plan. For the IMRT plan, target EUDS were reduced by 4%, 7.5%, and 10% for 2-mm, 4-mm, and 6-mm set-up errors respectively. However, even with set-up error, the mandible, spinal cord, and parotid EUDS always remained lower with the IMRT plan than with the 3D-CRT plan. We conclude that, when quantified by EUD, IMRT plan doses to OARS and targets are more sensitive to set-up error than are 3D-CRT-plan doses. However, as judged by the differences between target and OAR doses, IMRT retains its superiority over 3D-CRT, even in the presence of set-up error.

Publisher

MDPI AG

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3