Micro-CT Evaluation of Microgaps at Implant-Abutment Connection

Author:

Kowalski Jakub1,Puszkarz Adam K.2ORCID,Radwanski Mateusz3ORCID,Sokolowski Jerzy1,Cichomski Michal4ORCID,Bourgi Rim5ORCID,Hardan Louis5ORCID,Sauro Salvatore67ORCID,Lukomska-Szymanska Monika1ORCID

Affiliation:

1. Department of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland

2. Faculty of Material Technologies and Textile Design, Institute of Material Science of Textiles and Polymer Composites, Lodz University of Technology, 116 Zeromskiego Street, 90-924 Lodz, Poland

3. Department of Endodontics, Medical University of Lodz, 92-213 Lodz, Poland

4. Department of Material Technology and Chemistry, Faculty of Chemistry, University of Lodz, Pomorska 163, 90-236 Lodz, Poland

5. Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon

6. Dental Biomaterials and Minimally Invasive Dentistry, Departamento de Odontología, Facultad de Cienciasde la Salud, Universidad CEU-Cardenal Herrera, C/Del Pozo ss/n, Alfara del Patriarca, 46115 Valencia, Spain

7. Department of Therapeutic Dentistry, I. M. Sechenov First Moscow State Medical University, 119146 Moscow, Russia

Abstract

The assessment of microgaps at the implant–abutment interface is an important factor that may influence clinical success. Thus, the aim of this study was to evaluate the size of microgaps between prefabricated and customised abutments (Astra Tech, Dentsply, York, PA, USA; Apollo Implants Components, Pabianice, Poland) mounted on a standard implant. The measurement of the microgap was performed using micro-computed tomography (MCT). Due to 15-degree rotation of samples, 24 microsections were obtained. Scans were performed at four levels established at the interface between the abutment and the implant neck. Moreover, the volume of the microgap was evaluated. The size of the microgap at all measured levels varied from 0.1 to 3.7 µm for Astra and from 0.1 to 4.9 µm for Apollo (p > 0.05). Moreover, 90% of the Astra specimens and 70% of the Apollo specimens did not exhibit any microgaps. The highest mean values of microgap size for both groups were detected at the lowest portion of the abutment (p > 0.05). Additionally, the average microgap volume was greater for Apollo than for Astra (p > 0.05). It can be concluded that most samples did not exhibit any microgaps. Furthermore, the linear and volumetric dimensions of microgaps observed at the interface between Apollo or Astra abutments and Astra implants were comparable. Additionally, all tested components presented microgaps (if any) that were clinically acceptable. However, the microgap size of the Apollo abutment was higher and more variable than that of the Astra one.

Publisher

MDPI AG

Subject

General Materials Science

Reference75 articles.

1. Oral Health-Related Quality of Life of Patients Rehabilitated with Fixed and Removable Implant-Supported Dental Prostheses;Duong;Periodontol. 2000,2022

2. Indications and Contraindications of Dental Implants in Medically Compromised Patients: Update;Med. Oral Patol. Oral Cir. Bucal,2014

3. Gupta, R., Gupta, N., Kurt, K., and Weber, D. (2022). Bioceramics Calcium Phosphate, CRC Press.

4. Kowalski, J., Lapinska, B., Nissan, J., and Lukomska-Szymanska, M. (2021). Factors Influencing Marginal Bone Loss around Dental Implants: A Narrative Review. Coatings, 11.

5. Evaluation of Microgap Size and Microbial Leakage in the Connection Area of 4 Abutments with Straumann (ITI) Implant;Rismanchian;J. Oral Implantol.,2012

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3