Abstract
The suitability of CT and 3D scanners for craniometric proposes was tested using digital calipers when determining linear measurements, and a measuring cylinder was used for the accuracy of 3D printing of deer antlers obtained by the CT and 3D scanners. The resolution of digitized objects from a 3D scanner ranged from 0.008 mm to 0.122 mm. For mandibular dimensions, a positive deviation (p < 0.01) from the primary control measurement was recorded. The average antler volume measured with the cylinder was 60.47 cm3 at the first measurement, in the case of the CT scanner 61.62 cm3 and for the 3D scanner 64.76 cm3—both technologies exhibit a positive deviation from the primary measurement. Precise sensing and measurements can be used to evaluate the quality and evolution of wildlife populations, create digital museum collections, or to examine in detail certain traits such as antler and horn development or dentition.
Funder
project IGA (Internal Grants of the Faculty of Forestry and Wood Sciences, CzechUniversity of Life Sciences Prague)—Use of 3D scanners in craniometry and odontology
Subject
General Veterinary,Animal Science and Zoology
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Evidence and Identification;Fundamentals of Forensic Biology;2024
2. Craniometric indices of the skull of adult Nigerian indigenous Pigs (Sus scrofa);Journal of Sustainable Veterinary and Allied Sciences;2023-06-30