Abstract
Electron beam irradiation into type-Ib diamond is known as a good method for the creation of high concentration negatively-charged nitrogen-vacancy (NV−) centers by which highly sensitive quantum sensors can be fabricated. In order to understand the creation mechanism of NV− centers, we study the behavior of substitutional isolated nitrogen (P1 centers) and NV− centers in type-Ib diamond, with an initial P1 concentration of 40–80 ppm by electron beam irradiation up to 8.0 × 1018 electrons/cm2. P1 concentration and NV− concentration were measured using electron spin resonance and photoluminescence measurements. P1 center count decreases with increasing irradiation fluence up to 8.0 × 1018 electrons/cm2. The rate of decrease in P1 is slightly lower at irradiation fluence above 4.0 × 1018 electrons/cm2 especially for samples of low initial P1 concentration. Comparing concentration of P1 centers with that of NV− centers, it suggests that a part of P1 centers plays a role in the formation of other defects. The usefulness of electron beam irradiation to type-Ib diamonds was confirmed by the resultant conversion efficiency from P1 to NV− center around 12–19%.
Funder
Ministry of Education, Culture, Sports, Science and Technology
Subject
Nuclear and High Energy Physics,Atomic and Molecular Physics, and Optics
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献