The partial discharge (PD) measurement is an important method used in determining the condition of medium- and high-voltage cable insulation. Considering the propagation velocity of PD signals in power cables is necessary for determining the location of PD defects. However, the determination of velocity is not straightforward due to propagation-related attenuation and dispersion, which distorts the PD pulse waveform. This introduces a degree of uncertainty into the pulse velocity as well as the PD source locations determined based on that velocity, which is usually considered to be of constant value in PD analysis. This paper investigates the accuracy of the pulse propagation velocity measurement in power cables. Tests were performed on a medium voltage power cable in a laboratory setting using two sets of PD-specific measurement equipment: a high-frequency current transformer (HFCT) and an IEC 60270-compliant conventional measurement system. The propagation velocities and their statistical variability were determined using both devices to assess the uncertainty of the propagation velocity measurement. The results indicate that the measured velocity is slightly higher in the case of the HFCT and that the 50% peak threshold value should be used rather than the peak value of PD sensor response waveforms to increase the precision of velocity measurements.
Funder
Estonian Research Council
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction
Reference28 articles.
1. (2015). High-Voltage Test Techniques—Partial Discharge Measurements (Standard No. IEC 60270:2000/A1:2015).
2. Review on Partial Discharge Detection Techniques Related to High Voltage Power Equipment Using Different Sensors;Yaacob;Photonic Sens.,2014
3. Partial Discharge Detection in Medium Voltage and High Voltage Cables: Maximum Distance for Detection, Length of Cable, and Some Answers;Montanari;IEEE Electr. Insul. Mag.,2016
4. Wild, M., Tenbohlen, S., Gulski, E., Jongen, R., and de Vries, F. (2013, January 2–5). Practical Aspects of PD Localization for Long Length Power Cables. Proceedings of the 2013 IEEE Electrical Insulation Conference (EIC), Ottawa, ON, Canada.
5. van der Wielen, P.C.J.M., Veen, J., Wouters, P.A.A.F., and Steennis, E.F. (2005, January 6–9). On-Line Partial Discharge Detection of MV Cables with Defect Localisation (PDOL) Based on Two Time Synchronised Sensors. Proceedings of the CIRED 2005—18th International Conference and Exhibition on Electricity Distribution, Turin, Italy.