Calibration of In-Plane Center Alignment Errors in the Installation of a Circular Slide with Machine-Vision Sensor and a Reflective Marker

Author:

Jeong Hyungjin,Yu Jiwon,Lee DonghunORCID

Abstract

This paper describes a method for calibrating in-plane center alignment error (IPCA) that occurs when installing the circular motion slide (CMS). In this study, by combini ng the moving carriage of the CMS and the planar PKM (parallel kinematic mechanism) with the machine tool, the small workspace of the PKM is expanded, and the workpiece is placed on the table with the CMS installed is processed through the machine tool. However, to rigidly mount the CMS on the table, the preload between the guide and the support bearings must be adjusted with the eccentric bearing, and in this process, the IPCA occurs. After installing a reflective marker on the PKM, the PKM is slowly rotated along with the ring guide in the way of stop-and-go without the PKM’s own motion. Then, using a machine vision camera installed at the top of the CMS, the IPCA, which is the difference between the actual center position and the nominal center position of the CMS with respect to the camera, can be successfully calibrated through the circular fitting process. Consequently, it was confirmed that the IPCA of 0.37 mm can be successfully identified with the proposed method.

Funder

National Research Foundation of Korea

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3