Affiliation:
1. Lighting Technology Division, Electrical Power Engineering Institute, Faculty of Electrical Engineering, Warsaw University of Technology, Koszykowa 75, 00-661 Warsaw, Poland
Abstract
Luminance measurements are the least frequent of all photometric measurements. This article characterizes and systematizes the various methods of luminance measurement. In particular, the method of direct luminance measurement using modern luminance meters (ILMD) is described in detail. This paper presents the results of the study on the influence of the measurement distance on the luminance measurement results. Two ILMD meters (laboratory and portable) and a luminance standard were used in this study. The conducted research showed that an incorrectly chosen measuring distance can lead to significant measurement errors of up to several tens of percent. In addition, the possible impact of incorrect measurements on the design of an interior lighting installation was presented. It was shown that the selected interior lighting installation can consume more than 40 percent more electricity compared to the installation based on the correct luminance measurements of the luminaires with diffuse shades. In the final stage of the study, the definition of the photometric test distance for luminance measurements using ILMD was proposed. The test results can be particularly useful for the luminance measurements of OLEDs or the luminaires with diffuse luminous character. However, these results can also be used for luminance measurements of other light sources and luminaires.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction
Reference70 articles.
1. The total luminous flux measurement of high-power LEDs;Li;Proc. SPIE,2019
2. Markovič, M., Orgulan, A., and Sukič, P. (2022). Measuring System for Determining the Quality of LED Light Sources and an Overview of LED Light Bulbs for Household Use. Sensors, 22.
3. Romero, R.J.A., and Caro-Ruiz, C. (October, January 28). Uncertainty estimation in luminous flux measured with goniophotometers using monte carlo method. Proceedings of the 2020 IEEE PES Transmission and Distribution Conference and Exhibition—Latin America, T and D LA, Montevideo, Uruguay.
4. Lin, F., Li, T., Yin, D., Lai, L., and Xia, M. (2016, January 26–29). Research on effects of baffle position in an integrating sphere on the luminous flux measurement. Proceedings of the 8th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test, Measurement Technology, and Equipment, Suzhou, China.
5. Measurement and evaluation of selected parameters for non-directional household lamps;Wandachowicz;Prz. Elektrotech.,2018
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献