Evaluation of the Validity of Digital Optical Microscopy in the Assessment of Marginal Adaptation of Dental Adhesive Interfaces

Author:

Daher René,Krejci Ivo,di Bella Enrico,Marger Laurine

Abstract

Analysis of marginal adaptation of dental adhesive interfaces using scanning electron microscopy has proven to be a powerful nondestructive method to evaluate the quality of adhesion. This methodology is, however, time-consuming and needs expensive equipment. The purpose of this study was to evaluate the possibility and efficiency of using a digital optical microscope (DOM) to perform marginal analysis and to compare it with the scanning electron microscope (SEM) analysis. Fifteen defect-free molars were selected for this study. Class V cavities were prepared and restored with resin composite, and epoxy replicas were obtained from silicone impressions of the restored teeth. Custom-made image analysis software was then used to measure the percentage of the noncontinuous margins (NCM) of each sample. To compare the DOM to the gold standard, SEM, each sample was analyzed 10 times using the DOM and three times using the SEM, by the same experienced operator. The repeatability coefficient and concordance were evaluated, and a Bland and Altman analysis was used for comparison of the two methods of measurements. To validate the DOM analysis method, an ANOVA approach (Gage R R) was used. Repeatability and reproducibility, which are two components of precision to validate the DOM analysis system, were calculated. For this, the same restorations were analyzed by two additional operators three times with the DOM. The duration of each step of the analysis using both methods was also recorded as a secondary outcome. Regarding the repeatability of each method, the Friedman test showed no statistically significant difference within the repetitions of measurements by SEM and DOM (p = 0.523 and p = 0.123, respectively). Moreover, the Bland-Altman analysis revealed a bias of 0.86 and concluded no statistically significant difference between the two methods, DOM and SEM. ANOVA evaluated DOM measurement system variation including the variances of repeatability and reproducibility that represented, respectively, 0.3% and 4% of the variance components. Reproducibility or inter-operator variability represented the principal source of variability with a statistically significant difference (p = 0.024). The time required for analysis with SEM was almost double that of DOM. The use of digital optical microscopy appears to be a valid alternative to the SEM for the analysis of marginal adaptation of dental adhesive interfaces. Further studies to evaluate the effect of training of operators in digital optical microscopy could reveal higher accuracy for this method and inter-operator agreement when experience is gained.

Publisher

MDPI AG

Subject

Polymers and Plastics,General Chemistry

Reference25 articles.

1. Marginal adaptation, retention and fracture resistance of adhesive composite restorations on devital teeth with and without posts;Krejci;Oper. Dent.,2003

2. Shrinkage kinetics of a methacrylate- and a silorane-based resin composite: Effect on marginal integrity;Gregor;J. Adhes. Dent.,2013

3. Influence of Dentinal Fluid and Stress on Marginal Adaptation of Resin Composites

4. Effects of Thermocycling and Occlusal Force on Adhesive Composite Crowns

5. Clinical Status of Ten Dentin Adhesive Systems

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3