Abstract
This paper presents a study of PVC-P waterproofing membrane Specimens. The Specimens were taken from different segments of a flat roof after a service life of 11 years. The reason for analysing the condition of the Specimens was the apparent degradation of the waterproofing, which no longer guaranteed the watertightness of the roof. The analysis of the performance of the Specimens was based on the control of the mechanical properties, which were compared with the declared values. The mechanical properties of the degraded PVC-P waterproofing membranes with a polyester mesh backing, which are prescribed by the standards, do not usually deviate from the declared properties. This often poses a problem for liability and warranty claims due to the poor quality of the waterproofing membrane. There may be several causes of degradation of PVC-P. For this reason, in this paper, we present the possibility of controlling the properties of PVC-P waterproofing membranes using cyclic dynamic fatigue, microstructure analysis using scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). The results show that the cause of the deterioration of the PVC-P waterproofing membranes is often related to dehydrochlorination of the polymer. However, the deterioration of the mechanical properties of the PVC-P waterproofing membranes can be successfully demonstrated by cyclic dynamic fatigue.
Subject
Polymers and Plastics,General Chemistry
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献