Static and Dynamic Accuracy and Occlusion Robustness of SteamVR Tracking 2.0 in Multi-Base Station Setups
Author:
Kuhlmann de Canaviri LaraORCID, Meiszl KatharinaORCID, Hussein Vana, Abbassi PegahORCID, Mirraziroudsari Seyedeh DelaramORCID, Hake LaurinORCID, Potthast TobiasORCID, Ratert FabianORCID, Schulten TessaORCID, Silberbach Marc, Warnecke YannikORCID, Wiswede DanielORCID, Schiprowski Witold, Heß DanielORCID, Brüngel RaphaelORCID, Friedrich Christoph M.ORCID
Abstract
The tracking of objects and person position, orientation, and movement is relevant for various medical use cases, e.g., practical training of medical staff or patient rehabilitation. However, these demand high tracking accuracy and occlusion robustness. Expensive professional tracking systems fulfill these demands, however, cost-efficient and potentially adequate alternatives can be found in the gaming industry, e.g., SteamVR Tracking. This work presents an evaluation of SteamVR Tracking in its latest version 2.0 in two experimental setups, involving two and four base stations. Tracking accuracy, both static and dynamic, and occlusion robustness are investigated using a VIVE Tracker (3.0). A dynamic analysis further compares three different velocities. An error evaluation is performed using a Universal Robots UR10 robotic arm as ground-truth system under nonlaboratory conditions. Results are presented using the Root Mean Square Error. For static experiments, tracking errors in the submillimeter and subdegree range are achieved by both setups. Dynamic experiments achieved errors in the submillimeter range as well, yet tracking accuracy suffers from increasing velocity. Four base stations enable generally higher accuracy and robustness, especially in the dynamic experiments. Both setups enable adequate accuracy for diverse medical use cases. However, use cases demanding very high accuracy should primarily rely on SteamVR Tracking 2.0 with four base stations.
Funder
University of Applied Sciences and Arts Dortmund, Dortmund, Germany
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Reference34 articles.
1. Metaverse;Mystakidis;Encyclopedia,2022 2. Dębska, M., Polechoński, J., Mynarski, A., and Polechoński, P. (2019). Enjoyment and Intensity of Physical Activity in Immersive Virtual Reality Performed on Innovative Training Devices in Compliance with Recommendations for Health. Int. J. Environ. Res. Public Health, 16. 3. User experiences of virtual reality technologies for healthcare in learning: An integrative review;Haavisto;Behav. Inf. Technol.,2020 4. Ameler, T., Blohme, K., Brandt, L., Brüngel, R., Hensel, A., Huber, L., Kuper, F., Swoboda, J., Warnecke, M., and Warzecha, M. (2019, January 23–27). A Comparative Evaluation of SteamVR Tracking and the OptiTrack System for Medical Device Tracking. Proceedings of the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany. 5. Virtual-reality Simulation-based Training in Ultrasound;Konge;Ultraschall Med.-Eur. J. Ultrasound,2014
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|