Seismic Strengthening Effects of Full-Size Reinforced Concrete Frame Retrofitted with Novel Concrete-Filled Tube Modular Frame by Pseudo-Dynamic Testing

Author:

Kim Jin-Seon,Jung Ju-SeongORCID,Jung Dong-Keun,Kim Eui-Yong,Lee Kang-SeokORCID

Abstract

The present study proposes a new seismic retrofitting method using a concrete-filled tube modular frame (CFT-MF) system, a novel technique to overcome and improve the limitations of existing seismic strengthening methods. This CFT-MF seismic retrofitting method makes the most of the advantages of both concrete and steel pipes, thereby significantly improving constructability and increasing integration between the existing structure and the reinforcement joints. This method falls into the category of typical seismic retrofitting methods that focus on increasing strength, in which the required amount of seismic reinforcement can be easily estimated. Therefore, the method provides an easy solution to improving the strength of existing reinforced concrete (RC) structures with non-seismic details that are prone to shear failure. In the present study, a full-size two-story test frame modeled from existing domestic RC structures with non-seismic details was subjected to pseudo-dynamic testing. As a result, the effect of the CFT-MF system, when applied to existing RC structures, was examined and verified, especially as to its seismic retrofitting performance, i.e., restoring force characteristics, stiffness reinforcement, and seismic response control. In addition, based on the pseudo-dynamic testing results, a restoring force characteristics model was proposed to implement non-linear dynamic analysis of a structure retrofitted with the CFT-MF system (i.e., the test frame). Finally, based on the proposed restoring force characteristics, non-linear dynamic analysis was conducted, and the results were compared with those obtained by the pseudo-dynamic tests. The results showed that the RC frame (building) with no retrofitting measures applied underwent shear failure at a seismic intensity of 200 cm/s2, the threshold applied in seismic design in Korea. In contrast, in the frame (building) retrofitted with the CFT-MF system, only minor earthquake damage was observed, and even when the maximum seismic intensity (300 cm/s2) that may occur in Korean was applied, small-scale damage was observed. These results confirmed the validity of the seismic retrofitting method based on the CFT-MF system developed in the present study. The non-linear dynamic analysis and the pseudo-dynamic test showed similar results, with an average deviation of 10% or less in seismic response load and displacement.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3