Why Determining the Native Length Change Pattern of Medial Patellofemoral Ligament Is Still a Challenge: State-of-the-Art Review of Potential Sources of Heterogeneity within Studies Evaluating Isometry of MPFL

Author:

Mostowy MarcinORCID,Kwas Katarzyna,Ruzik KacperORCID,Koźlak Magdalena,Kwapisz Adam,Brzezinska Eva,Malinowski Konrad,Domżalski Marcin E.

Abstract

Background: In the literature there are divergent results as to the native MPFL length change pattern. The reason for such divergent results may be the heterogeneity of design of studies analyzing MPFL isometry. The hypothesis of this review was that studies assessing MPFL length change pattern are highly heterogenous. The aim was to present a state-of-the-art review of sources of this heterogeneity. Materials and Methods: A total of 816 records were identified through the initial search of MEDLINE and Scopus databases. After eligibility assessment, 10 original articles and five reviews were included. In the included studies, the following 15 potential sources of heterogeneity were assessed: number of patients/cadavers, age, males to females ratio (demographics), identification of measured fibers, measurement method, measurement precision, quadriceps muscle activity, iliotibial band activity, hamstrings activity (study design), patellar height, trochlear or patellar dysplasia, femoral anteversion, mechanical axis of the limb, tibial tubercle–trochlear groove distance, and condylar anteroposterior dimensions (morphology). Each variable was graded in every included article with 1 point if reported precisely and not introducing bias; or with 0 points if reported not precisely, introducing bias, or not reported at all. Results: Within original articles, the highest achieved score was 10 out of 15 possible points with mean score of 6.7, SD = 2.37, and minimum score of just 3 out of 15 points. In the demographics section, mean score was 2.4, SD = 0.8 (80% of maximum possible score of 3); in the study design section it was 3.1, SD = 1.87 (52% of maximum possible score of 6); and in the morphology section it was 1.5, SD = 1.43 (25% of maximum possible score of 6). Conclusions: There is high heterogeneity and incomplete reporting of potential sources of bias in studies assessing native MPFL length change pattern. Future investigators should be aware of the presented factors and their potential impact on MPFL isometry. All methodologic factors should be meticulously reported. Detailed description of demographic data is already a standard; however, authors should more extensively report variables concerning study design and morphology of patients’ patellofemoral joint. Furthermore, future studies should try to meticulously simulate the real-life working environment of MPFL and ensure usage of proper measurement methods.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3