Abstract
Several factors cause the output degradation of the photovoltaic (PV) module. The main affecting elements are the higher PV module temperature, the shaded cell, the shortened or conducting bypass diodes, and the soiled and degraded PV array. In this paper, we introduce an image processing technique that automatically identifies the module generating the hot spots in the solar module. In order to extract feature points, we used the maximally stable extremal regions (MSER) method, which derives the area of interest by using the inrange function, using the blue color of the PV module. We propose an effective matching method for feature points and a homography translation technique. The temperature data derivation method and the normal/ abnormal decision method are described in order to enhance the performance. The effectiveness of the proposed system was evaluated through experiments. Finally, a thermal image analysis of approximately 240 modules was confirmed to be 97% consistent with the visual evaluation in the experimental results.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
22 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献