Lab on a Chip Device for Diagnostic Evaluation and Management in Chronic Renal Disease: A Change Promoting Approach in the Patients’ Follow Up
-
Published:2023-03-12
Issue:3
Volume:13
Page:373
-
ISSN:2079-6374
-
Container-title:Biosensors
-
language:en
-
Short-container-title:Biosensors
Author:
Borriello Margherita1, Tarabella Giuseppe2, D’Angelo Pasquale2ORCID, Liboà Aris2, Barra Mario3ORCID, Vurro Davide2, Lombari Patrizia1, Coppola Annapaola1, Mazzella Elvira4, Perna Alessandra F.4ORCID, Ingrosso Diego1
Affiliation:
1. Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, via L. De Crecchio, 7, 80138 Naples, Italy 2. IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy 3. CNR-SPIN, c/o Dipartimento di Fisica “Ettore Pancini”, P.le Tecchio, 80, 80125 Naples, Italy 4. Department of Translational Medical Science, University of Campania “Luigi Vanvitelli”, via Via Pansini, Bldg 17, 80131 Naples, Italy
Abstract
Lab-on-a-chip (LOC) systems are miniaturized devices aimed to perform one or several analyses, normally carried out in a laboratory setting, on a single chip. LOC systems have a wide application range, including diagnosis and clinical biochemistry. In a clinical setting, LOC systems can be associated with the Point-of-Care Testing (POCT) definition. POCT circumvents several steps in central laboratory testing, including specimen transportation and processing, resulting in a faster turnaround time. Provider access to rapid test results allows for prompt medical decision making, which can lead to improved patient outcomes, operational efficiencies, patient satisfaction, and even cost savings. These features are particularly attractive for healthcare settings dealing with complicated patients, such as those affected by chronic kidney disease (CKD). CKD is a pathological condition characterized by progressive and irreversible structural or functional kidney impairment lasting for more than three months. The disease displays an unavoidable tendency to progress to End Stage Renal Disease (ESRD), thus requiring renal replacement therapy, usually dialysis, and transplant. Cardiovascular disease (CVD) is the major cause of death in CKD, with a cardiovascular risk ten times higher in these patients than the rate observed in healthy subjects. The gradual decline of the kidney leads to the accumulation of uremic solutes, with negative effect on organs, especially on the cardiovascular system. The possibility to monitor CKD patients by using non-invasive and low-cost approaches could give advantages both to the patient outcome and sanitary costs. Despite their numerous advantages, POCT application in CKD management is not very common, even if a number of devices aimed at monitoring the CKD have been demonstrated worldwide at the lab scale by basic studies (low Technology Readiness Level, TRL). The reasons are related to both technological and clinical aspects. In this review, the main technologies for the design of LOCs are reported, as well as the available POCT devices for CKD monitoring, with a special focus on the most recent reliable applications in this field. Moreover, the current challenges in design and applications of LOCs in the clinical setting are briefly discussed.
Subject
Clinical Biochemistry,General Medicine,Analytical Chemistry,Biotechnology,Instrumentation,Biomedical Engineering,Engineering (miscellaneous)
Reference95 articles.
1. Introduction, theory, and technology;Reyes;Anal. Chem,2002 2. Lab-on-a-chip that takes the chip out of the lab;Mohammed;Nature,2022 3. Diagnosis of COVID-19 for controlling the pandemic: A review of the state-of-the-art;Taleghani;Biosens. Bioelectron.,2021 4. Integrated sample-to-detection chip for nucleic acid test assays;Prakash;Biomed Microdevices,2016 5. Azizipour, N., Avazpour, R., Rosenzweig, D.H., Sawan, M., and Ajji, A. (2020). Evolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip. Micromachines, 11.