Affiliation:
1. Electric Power Research Institute of Yunnan Electric Power Grid Co., Ltd., Kunming 650217, China
2. The Key Laboratory of Smart Grid of Ministry of Education, Tianjin University, Tianjin 300072, China
Abstract
As the demand for power supply stability and reliability in the active distribution network (ADN) increases, the primary and secondary integrated intelligent switch (PSIIS) has become the primary choice for smart grid transformation in many weak infrastructure areas. However, the number of PSIISs that can be configured is often limited. It is necessary to comprehensively utilize the measurement data and sectional capabilities of PSIISs through the optimal configuration method to find the optimal configuration scheme. Therefore, fault observability-related indexes (FORIs) are proposed based on the functional characteristics of PSIISs. These indexes include fault type observability, fault location observability, fault current distribution characteristics observability, transition resistance observability, and weak infrastructure area observability. An optimization configuration model of PSIISs considering the comprehensive fault observability (CFO) is constructed. The adaptive genetic algorithm (AGA) is selected as the model-solving method. Subsequently, an optimal configuration method of PSIISs considering CFO is proposed. Finally, an example analysis is conducted in MATLAB to verify the effectiveness and feasibility of the proposed method. This optimal configuration method aims to maximize the use of a limited number of PSIISs by considering CFO, and the AGA proves to be an effective tool in solving the optimal configuration scheme.
Funder
Yunnan Fundamental Research Projects
Reference20 articles.
1. Research and Analysis on the Application of Intelligent Integrated Switches of Primary and Secondary Fusion;Zhang;J. Electr. Eng.,2022
2. Game-Theoretic Applications for Decision-Making Behavior on the Energy Demand Side: A Systematic Review;Ji;Prot. Control Mod. Power Syst.,2024
3. Curvature Quantified Douglas-Peucker-Based Phasor Measurement Unit Data Compression Method for Power System Situational Awareness;Tan;Prot. Control Mod. Power Syst.,2024
4. Piesciorovsky, E.C., Warmack, R.J.B., and Polsky, Y. (2023). Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events. Energies, 16.
5. Optimal Placement Method for Harmonic Resonance Monitoring Points Considering Uncertainties of System Parameters;Jiang;Autom. Electr. Power Syst.,2021