Abstract

In rehabilitating orientation and mobility (O&M) for visually impaired people (VIP), the measurement of spatio-temporal gait and postural parameters is of specific interest for rehabilitators to assess performance and improvements in independent mobility. In the current practice of rehabilitation worldwide, this assessment is carried out in people with estimates made visually. The objective of this research was to propose a simple architecture based on the use of wearable inertial sensors for quantitative estimation of distance traveled, step detection, gait velocity, step length and postural stability. These parameters were calculated using absolute orientation angles. Two different sensing architectures were tested for gait according to a selected biomechanical model. The validation tests included five different walking tasks. There were nine visually impaired volunteers in real-time acquisitions, where the volunteers walked indoor and outdoor distances at different gait velocities in their residences. The ground truth gait characteristics of the volunteers in five walking tasks and an assessment of the natural posture during the walking tasks are also presented in this article. One of the proposed methods was selected for presenting the lowest absolute error of the calculated parameters in all of the traveling experimentations: 45 walking tasks between 7 and 45 m representing a total of 1039 m walked and 2068 steps; the step length measurement was 4.6 ± 6.7 cm with a mean of 56 cm (11.59 Std) and 1.5 ± 1.6 relative error in step count, which compromised the distance traveled and gait velocity measurements, presenting an absolute error of 1.78 ± 1.80 m and 7.1 ± 7.2 cm/s, respectively. The results suggest that the proposed method and its architecture could be used as a tool for assistive technology designed for O&M training to assess gait parameters and/or navigation, and that a sensor placed in the dorsal area is sufficient to detect noticeable postural changes that compromise heading, inclinations and balancing in walking tasks.

Funder

Ministerio de Ciencia, Innovación y Universidades

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference21 articles.

1. Temporal spatial parameters analysis of the gait in children with vision impairment;Sankako;Int. J. Orientat. Mobil.,2016

2. Wearable inertial sensors to measure gait and posture characteristic differences in older adult fallers and non-fallers: A scoping review;Patel;Gait Posture,2020

3. Developing Walking Assistants for Visually Impaired People: A Review;Islam;IEEE Sens. J.,2019

4. Techniques for Constructing Indoor Navigation Systems for the Visually Impaired: A Review;Kandalan;IEEE Trans. Hum.-Mach. Syst.,2020

5. WeAllWalk;Flores;ACM Trans. Access. Comput.,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3