Affiliation:
1. State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
Abstract
(1) Background: The imaging energy range of a typical Compton camera is limited due to the fact that scattered gamma photons are seldom fully absorbed when the incident energies are above 3 MeV. Further improving the upper energy limit of gamma-ray imaging has important application significance in the active interrogation of special nuclear materials and chemical warfare agents, as well as range verification of proton therapy. (2) Methods: To realize gamma-ray imaging in a wide energy range of 0.3~7 MeV, a principle prototype, named a portable three-layer Compton camera, is developed using the scintillation detector that consists of an silicon photomultiplier array coupled with a Gd3Al2Ga3O12:Ce pixelated scintillator array. Implemented in a list-mode maximum likelihood expectation maximization algorithm, a far-field energy-domain imaging method based on the two interaction events is applied to estimate the initial energy and spatial distribution of gamma-ray sources. The simulation model of the detectors is established based on the Monte Carlo simulation toolkit Geant4. The reconstructed images of a 133Ba, a 137Cs and a 60Co point-like sources have been successfully obtained with our prototype in laboratory tests and compared with simulation studies. (3) Results: The proportion of effective imaging events accounts for about 2%, which allows our prototype to realize the reconstruction of the distribution of a 0.05 μSv/h 137Cs source in 10 s. The angular resolution for resolving two 137Cs point-like sources is 15°. Additional simulated imaging of the 6.13 MeV gamma-rays from 14.1 MeV neutron scattering with water preliminarily demonstrates the imaging capability for high incident energy. (4) Conclusions: We conclude that the prototype has a good imaging performance in a wide energy range (0.3~7 MeV), which shows potential in several MeV gamma-ray imaging applications.
Funder
National Natural Science Foundation of China
Science Foundation of State Key Laboratory of NBC Protection for Civilians
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Reference31 articles.
1. Parajuli, R.K., Sakai, M., Parajuli, R., and Tashiro, M. (2022). Development and Applications of Compton Camera—A Review. Sensors, 22.
2. Gamma-ray astrophysics in the MeV range: The ASTROGAM concept and beyond;Tatischeff;Exp. Astron.,2021
3. First demonstration of multi-color 3-D in vivo imaging using ultra-compact Compton camera;Kishimoto;Sci. Rep.,2017
4. High-precision Compton imaging of 4.4 MeV prompt gamma-ray toward an on-line monitor for proton therapy;Mochizuki;Nucl. Instrum. Methods Phys. Res. Sect. A,2019
5. Monitoring ion beam therapy with a Compton camera: Simulation studies of the clinical feasibility;Fontana;IEEE Trans. Radiat. Plasma Med. Sci.,2020
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献