Attitude Correlated Frames Based Calibration Method for Star Sensors

Author:

Ma Liheng1ORCID,Xiao Shenglong2,Tang Wenjun2,Luo Xiao2,Zhang Su1

Affiliation:

1. College of Ordnance Engineering, Naval University of Engineering, Wuhan 430033, China

2. Guangzhou Bureau of the Department of Naval Equipment, Guangzhou 511464, China

Abstract

Star sensors undergo laboratory calibration before they leave the factory. In addition, recalibration is necessary after they experience vibration, deformation, etc. Using the analysis of attitude-dependent and attitude-independent interstar angular invariance calibration methods (IAICMs) as a reference, an attitude-correlated frame-based calibration method (ACFCM) is proposed in this work, which combines the advantages of both methods. Using outdoor star observations, the ACFCM correlates star image frames obtained at different times via a strapdown gyro unit. As a result, the number of efficient star images for calibration increases rapidly and the distribution of star images becomes much more uniform, thus improving the calibration accuracy of the star sensor. A simulation and experimental tests were designed and carried out. Both the simulation and experimental results verify the feasibility of the proposed ACFCM method. Furthermore, by comparing our method with the IAICMs, the repeatability and reliability of the principal point obtained from the calibration with the ACFCM method proposed in this work were significantly improved.

Funder

National Natural Science Foundation of China

Individual Science Foundation of the Naval University of Engineering

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference25 articles.

1. Accuracy performance of star trackers—A tutorial;Liebe;IEEE Trans. Arespace Electron. Syst.,2002

2. Three-axis attitude accuracy of better than 5 arcseconds obtained for the star sensor in a long-term on-ship dynamic experiment;Ma;Appl. Opt.,2018

3. Star tracker parametric analysis for autonomous calibration;Xing;J. Tsinghua Univ. (Sci. Technol.),2005

4. Optical system error analysis and calibration method of high-accuracy star trackers;Sun;Sensors,2013

5. Autonomous recalibration of star trackers;John;IEEE Sens. J.,2018

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献