Attitude Correlated Frames Based Calibration Method for Star Sensors

Author:

Ma Liheng1ORCID,Xiao Shenglong2,Tang Wenjun2,Luo Xiao2,Zhang Su1

Affiliation:

1. College of Ordnance Engineering, Naval University of Engineering, Wuhan 430033, China

2. Guangzhou Bureau of the Department of Naval Equipment, Guangzhou 511464, China

Abstract

Star sensors undergo laboratory calibration before they leave the factory. In addition, recalibration is necessary after they experience vibration, deformation, etc. Using the analysis of attitude-dependent and attitude-independent interstar angular invariance calibration methods (IAICMs) as a reference, an attitude-correlated frame-based calibration method (ACFCM) is proposed in this work, which combines the advantages of both methods. Using outdoor star observations, the ACFCM correlates star image frames obtained at different times via a strapdown gyro unit. As a result, the number of efficient star images for calibration increases rapidly and the distribution of star images becomes much more uniform, thus improving the calibration accuracy of the star sensor. A simulation and experimental tests were designed and carried out. Both the simulation and experimental results verify the feasibility of the proposed ACFCM method. Furthermore, by comparing our method with the IAICMs, the repeatability and reliability of the principal point obtained from the calibration with the ACFCM method proposed in this work were significantly improved.

Funder

National Natural Science Foundation of China

Individual Science Foundation of the Naval University of Engineering

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference25 articles.

1. Accuracy performance of star trackers—A tutorial;Liebe;IEEE Trans. Arespace Electron. Syst.,2002

2. Three-axis attitude accuracy of better than 5 arcseconds obtained for the star sensor in a long-term on-ship dynamic experiment;Ma;Appl. Opt.,2018

3. Star tracker parametric analysis for autonomous calibration;Xing;J. Tsinghua Univ. (Sci. Technol.),2005

4. Optical system error analysis and calibration method of high-accuracy star trackers;Sun;Sensors,2013

5. Autonomous recalibration of star trackers;John;IEEE Sens. J.,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3