Comparative Analysis of Temperature Variation with Three Continuous Wave Obturation Systems in Endodontics: An In Vitro Study

Author:

Mena-Álvarez JesúsORCID,Ruiz-Barrio Maria,Quispe-López NorbertoORCID,de Pedro-Muñoz Ana,Rico-Romano Cristina

Abstract

The aim of this study was to assess temperature changes with different continuous wave obturation systems when downpacking to 2 mm and 4 mm from the apical foramen in an open system not simulating the surrounding biological structures at body temperature. Sixty single-rooted teeth were divided into three groups: (A) Dia-Duo® (DiaDent Group International, Cheongju-si, Korea), (B) Elements Free® (Kerr Corporation, Orange, CA, USA) and (C) Calamus® (Dentsply Sirona, Ballaigues, Switzerland). The root canals were instrumented with Protaper Gold (Dentsply Sirona, Ballaigues, Switzerland) to size F2 (25.08). The root canals were filled by a continuous wave using an AH Plus® sealer (Dentsply Sirona). Temperatures during the obturation procedure were measured by a thermal imaging camera (Testo 875-1®) perpendicular to a vice where the teeth were held at −2 mm and −4 mm from the apical foramen. Comparisons were made by applying Student’s t-test and ANOVA (p = 0.05). The continuous wave technique at −2 mm with the Dia-Duo system® emitted average temperatures of 37.3 °C, Elements Free® emitted 39.85 °C and Calamus® emitted 40.16 °C. At −4 mm, the Dia-Duo system® emitted average temperatures of 34.81 °C, Elements Free® emitted 33.73 °C and Calamus® emitted 32.91 °C. There were significant differences between continuous waves at −2 mm and at −4 mm (p < 0.05). Dia-Duo® was the only system that did not present significant differences between the two lengths (p = 0.197). Regarding the heat emitted, the best system was Elements Free®, since, at −2 mm, it emitted the highest temperature without going above 47 °C. The Dia-Duo® system had lower temperatures. It could be concluded that not all systems transmit the same temperature to the apex and, therefore, to the periapical tissues. The surrounding conditions, such as temperature and humidity, have not been considered in this study.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3