Wear Analysis of Four Different Single-File Reciprocating Instruments before and after Four Uses in Simulated Root Canals

Author:

Zanza AlessioORCID,Reda RodolfoORCID,Familiari Giuseppe,Nottola Stefania Annarita,Di Nardo DarioORCID,Testarelli LucaORCID,Donfrancesco OrlandoORCID

Abstract

The aim of this study is to assess the surface alterations of four reciprocating instruments before and after the shaping of four resin-simulated root canals. The following four different reciprocating instruments are selected: 10 Reciproc Blue (RB25), 10 WaveOne Gold (WOG), 10 EdgeOne Fire (EOF) and 10 recently introduced instruments OneRECI (OR), for a total of 40 new instruments. Before root canal shaping, each instrument is mounted on a stub in a standardized position and observed using a scanning electron microscope (SEM) to detect any surface alteration, such as microfractures, metal defects, deformations, blunt and disruption of cutting edges, debris, pitting and tip flattening. Micrographs are acquired at the level of the tip, 4 mm, 8 mm and 12 mm from it. After that, each instrument is used in four simulated resin root canals. SEM observation was repeated after the simulated clinical use to assess the wear resistance of the instruments. Surface alterations are registered before and after instrumentation and statistical analysis is performed using a Chi-Square test to verify homogeneity of defects distribution and GLM to evaluate the differences of RMS at baseline and after use for both groups (α level 0.05). Before simulated clinical uses, no alterations are found except for three cases of EOF with metal strips in correspondence to the tip, disruption of the cutting edge of WOG and oily spotting on two different OR. After simulated clinical use, EOF shows a statistically significant difference in terms of spiral distortion and flattening of the cutting edges. The OR shows the highest presence of debris despite the ultrasonic cleaning procedures. No instrument fractures are observed. EOF should be discarded after four clinical uses and carefully inspected after each insertion into root canals. Moreover, tough attention should be paid during disinfection and cleaning procedures after instrumentation considering the copious debris detected in each instrument, particularly in OR.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3