Cooling Strategy Optimization of Cylindrical Lithium-Ion Battery Pack via Multi-Counter Cooling Channels

Author:

Jeon Hyeonchang1,Hong Seokmoo2ORCID,Yun Jinwon3,Han Jaeyoung24

Affiliation:

1. Department of Mechanical Engineering, Graduate School of Kongju National University, 1223-24, Cheonan-daero, Seobuk-gu, Cheonan-si 31080, Republic of Korea

2. Department of Future Automotive Engineering, Kongju National University, 1223-24, Cheonan-daero, Seobuk-gu, Cheonan-si 31080, Republic of Korea

3. Department of Energy and Mineral Resources Engineering, Dong-A University, 37, Nakdong-daero 550beon-gil, Saha-gu, Busan 49315, Republic of Korea

4. Institute of Green Car Technology, Kongju National University, 1223-24, Cheonan-daero, Seobuk-gu, Cheonan-si 31080, Republic of Korea

Abstract

This study focused on the design of a battery pack cooling channel based on a Tesla Model S electric car. This study aimed to achieve a balance between cooling efficiency and pressure drop while maintaining safe and optimal operating temperatures for the batteries. A cooling channel design similar to the basic type employed in the Tesla Model S using 448 cylindrical Li-ion batteries was considered. Consequently, important parameters, such as the maximum temperature and temperature difference in the battery cells in a module, as well as the pressure drop of the coolant, were analyzed. In addition, the characteristics of the temperature changes in each cooling channel shape were investigated. The temperature limit for the battery in a module and the temperature limit difference were set to 40 °C and 5 °C, respectively, to evaluate the performance of the cooling system. Further, the effects of discharge rates (3C and 5C), cooling channel shapes (counter flow and parallel types), and coolant inlet velocities (0.1, 0.2, 0.3, and 0.4 m/s) on battery thermal management were analyzed. The results revealed that the parallel type channel yielded a lower pressure drop than the basic type channel; however, it was not as effective in removing heat from the battery. In contrast, the counter flow type channel effectively removed heat from the batteries with a higher coolant pressure drop in the channel. Therefore, a multi-counter flow type cooling channel combining the advantages of both these channels was proposed to decrease the pressure drop while maintaining appropriate operating temperatures for the battery module. The proposed cooling channel exhibited an excellent cooling performance with lower power consumption and better heat transfer characteristics. However, relatively minimal differences were confirmed for the maximum temperature and temperature difference in the battery module compared with the counter flow type. Therefore, the proposed cooling channel type can be implemented to ensure the optimal temperature operation of the battery module and to decrease system power consumption.

Funder

Ministry of Education

Korean government

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3