Feature-Oriented CBCT Self-Calibration Parameter Estimator for Arbitrary Trajectories: FORCAST-EST

Author:

Tönnes Christian12ORCID,Zöllner Frank G.12ORCID

Affiliation:

1. Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1, 68159 Mannheim, Germany

2. Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1, 68159 Mannheim, Germany

Abstract

Background: For the reconstruction of Cone-Beam CT volumes, the exact position of each projection is needed; however, in some situations, this information is missing. Purpose: The development of a self-calibration algorithm for arbitrary CBCT trajectories that does not need initial positions. Methods: Projections are simulated in a spherical grid around the center of rotation. Through using feature detection and matching, an acquired projection is compared to each simulated image in this grid. The position with the most matched features was used as a starting point for a fine calibration with a state-of-the-art algorithm. Evaluation: This approach is compared with the calibration of nearly correct starting positions when using FORCASTER and CMA-ES minimization with a normalized gradient information (NGI) objective function. The comparison metrics were the normalized root mean squared error, structural similarity index, and the dice coefficient, which were evaluated on the segmentation of a metal object. Results: The parameter estimation for a regular Cone-Beam CT with a 496 projection took 1:26 h with the following metric values: NRMSE = 0.0669; SSIM = 0.992; NGI = 0.75; and Dice = 0.96. FORCASTER with parameter estimation took 3:28 h with the following metrics: NRMSE = 0.0190; SSIM = 0.999; NGI = 0.92; and Dice = 0.99. CMA-ES with parameter estimation took 5:39 h with the following metrics: NRMSE = 0.0037; SSIM = 1.0; NGI = 0.98; and Dice = 1.0. Conclusions: The proposed algorithm can determine the parameters of the projection orientations for arbitrary trajectories with enough accuracy to reconstruct a 3D volume with low errors.

Funder

Federal Ministry of Education and Research

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3