Accuracy of Two Variants of 3D-Printed Insertion Guides for Orthodontic Mini-Implants: An Ex Vivo Study in Human Cadavers

Author:

Pliska Annika1,Schiavon Lucia2,Brunello Giulia23ORCID,Wilmes Benedict1,Schwarz-Herzke Beryl4,Drescher Dieter1,Becker Kathrin1ORCID

Affiliation:

1. Department of Orthodontics, University Hospital of Düsseldorf, 40225 Düsseldorf, Germany

2. Department of Neurosciences, School of Dentistry, University of Padova, 35128 Padova, Italy

3. Department of Oral Surgery, University Hospital of Düsseldorf, 40225 Düsseldorf, Germany

4. Institute for Anatomy II, University Hospital of Düsseldorf, 40225 Düsseldorf, Germany

Abstract

Insertion guides are becoming popular for orthodontic mini-implant positioning. The aim of this study was to evaluate and compare the accuracy of two different mini-implant insertion guides, with or without pre-drilling, in a human cadaveric model. Maxillary casts of six fresh frozen specimens were digitized to create insertion guides. Sixty mini-implants were randomly inserted with full-arch or skeletonized guides, either with or without predrilling. Pre- and post-treatment CBCTs were superimposed using rigid registration. Transformation matrices of the planned and real positions were obtained, and distances at the mini-implant neck and apex, as well as the angular deviation, were calculated. The Kruskal–Wallis test was performed, followed by a post hoc test when indicated. Out of 60 inserted mini-implants, 46 could be evaluated. Of these, 10 initially assigned to no pre-drilling required this procedure due to very high bone density. Therefore, 32 implants were inserted with pre-drilling (n = 15 full-arch; n = 17 skeletonized) and 14 without (n = 7 full-arch; n = 7 skeletonized). The lowest mean deviation at the neck was 1.22 ± 0.6 mm, registered in the full-arch/pre-drilling group. The skeletonized/no pre-drilling group presented the lowest mean values at the apex, i.e., 1.72 ± 1.22 mm, as well as the lowest mean angular deviation, i.e., 8.23 ± 4.24°. Significant differences among groups were observed only at the neck, with higher mean deviation in the skeletonized/pre-drilling group than in the full-arch/pre-drilling one (p = 0.014). In conclusion, within the limitations of the study, rather high deviations between planned and real mini-implant positions were found. Further studies are needed on how to improve the accuracy within in vivo settings.

Funder

PSM Medical

Easy Driver

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3