Continuous-Flow Microwave Heating Inactivation Kinetics of α-Amylase from Bacillus subtilis and a Comparison with Conventional Heating Conditions
-
Published:2023-08-14
Issue:16
Volume:13
Page:9220
-
ISSN:2076-3417
-
Container-title:Applied Sciences
-
language:en
-
Short-container-title:Applied Sciences
Author:
Tong Zhen1,
Ramaswamy Hosahalli S.1ORCID
Affiliation:
1. Department of Food Science, Macdonald Campus, McGill University, 21111 Lakeshore Road, Ste Anne de Bellevue, QC H9X 3V9, Canada
Abstract
The inactivation kinetics of an α-amylase enzymatic time-temperature integrator (TTI) from Bacillus subtilis (BAA) under continuous-flow microwave (MW) and conventional heating conditions were evaluated and compared in this study. The TTI dispersed in a buffer solution (pH 5.0 to 6.9) at 20 °C initially, and it was continuously circulated through two helical coils connected in a series for heating. The two coils were positioned in two domestic microwave ovens (2450 MHz and 1000 W nominal capacity each) and connected by a short tube. The sample flow rates were adjusted to result in a specific exit temperature in the range of 65 to 80 °C. A short fully insulated helical coil at the exit of the second oven was used as a holding tube. Test samples were drawn either at the exit of the second MW oven or immediately after the holding tube. The decimal reduction times obtained under conventional batch heating conditions decreased from 66 to 24 s as the temperature changed from 70 to 75 °C at pH 5.0 while they decreased from 8 to 5 s under MW in the same temperature range, but at pH 6.0, they increased both under conventional and microwave heating conditions (138 to 120 s and 89 to 61 s, respectively). The D-values under conventional thermal holding were four–eight times higher than under a continuous-flow MW heating condition. By varying the pH, the D-values could be modified to suit the validation of appropriate processing conditions.
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Reference29 articles.
1. Microwave properties and heating characteristics of foods;Mudgett;Food Technol.,1986
2. Microwave food processing. A Scientific Status Summary by the lFT Expert Panel on Food Safety and Nutrition;Mudgett;Food Technol.,1989
3. Use of microwave ovens to pasteurize milk;Knutson;J. Food Prot.,1988
4. Heating characteristics of milk constituents in a microwave pasteurization system;Kudra;J. Food Sci.,1991
5. A microwave system for continuous pasteurization of orange juice;Nikdel;Proc. Fla. State Hort. Soc.,1992