Spain’s high winter weather-associated death count, the second largest in Europe, can be attributed primarily to the low construction standards of its social housing, particularly the stock built prior to the entry into effect of the earliest statutory provisions on envelope quality. Hence, improving building envelopes to both reduce energy consumption and raise occupant comfort levels is important. Air leakage is one of the factors with the greatest impact on indoor comfort and domestic energy consumption. This study explores the sensitivity of energy consumption to that parameter in a series of types of social housing built between 1950 and 1979 in five Mediterranean climate zones. Demand in a total of 53 housing units located in 21 developments was simulated to that end. The findings show that air permeability has a significant effect on wintertime demand in the sample studied. Although the impact is greater in the more severe climates where it is estimated to be over 10 kWh/m2, it may also affect energy consumption in mild climates.