Abstract
Air entrainment in a stepped spillway is very important to protect the spillway from cavitation damage. The inception point is the location where air starts entering the non-aerated flow zone. The inception point location depends on different parameters, such as the discharge, step height, and step shape. In this paper, various stepped spillways, including flat steps, pooled steps, and round steps with different step heights were numerically simulated using the volume of fluid and realizable k-ε models. The results indicate that the inception point location moves downwards with the increase of the discharge of the stepped spillways. The length of the non-aerated flow zone increases with the discharge. The inception point location moves downwards as the step height decreases and the step number increases at the same discharge. The inception point location of the round stepped spillway model is much closer to the spillway crest than that of the flat stepped spillway with the same number of steps. The inception point location of the pooled stepped spillway is closer to the spillway crest than that of the flat stepped spillway, but more downstream than that of the round stepped spillway.
Funder
National Natural Science Foundation of China
Zhejiang Provincial Natural Science Foundation of China
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
20 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献