Abdominal Aortic Aneurysm Detection in Bioelectrical Impedance Cardiovascular Screenings—A Pilot Study

Author:

Hofmann Amun1ORCID,Shoumariyeh Tarik1,Domenig Christoph2,Skrabal Falko3,Kovarik Johannes1

Affiliation:

1. Department of Internal Medicine III, Division of Nephrology and Dialysis, Medical University of Vienna, 1090 Vienna, Austria

2. Department of General Surgery, Division of Vascular Surgery, Medical University of Vienna, 1090 Vienna, Austria

3. Institute of Cardiovascular & Metabolic Medicine, 8010 Graz, Austria

Abstract

Screening and diagnosing abdominal aortic aneurysms (AAA) are currently dependent on imaging studies such as ultrasound or computed tomography angiography. All imaging studies offer distinct advantages but also suffer from inherent limitations such as examiner dependency or ionizing radiation. Bioelectrical impedance analysis has previously been investigated with respect to its use in the detection of several cardiovascular and renal pathologies. The present pilot study assessed the feasibility of AAA detection based on bioimpedance analysis. In this single-center exploratory pilot study, measurements were conducted among three different cohorts: patients with AAA, end-stage renal disease patients without AAA, and healthy controls. The device used in the study, CombynECG, is an open-market accessible device for segmental bioelectrical impedance analysis. The data was preprocessed and used to train four different machine learning models on a randomized training sample (80% of the full dataset). Each model was then evaluated on a test set (20% of the full dataset). The total sample included 22 patients with AAA, 16 chronic kidney disease patients, and 23 healthy controls. All four models showed strong predictive performance in the test partitions. Specificity ranged from 71.4 to 100%, while sensitivity ranged from 66.7 to 100%. The best-performing model had 100% accuracy for classification when applied to the test sample. Additionally, an exploratory analysis to approximate the maximum AAA diameter was conducted. An association analysis revealed several impedance parameters that might possess predictive ability with respect to aneurysm size. AAA detection via bioelectrical impedance analysis is technically feasible and appears to be a promising technology for large-scale clinical studies and routine clinical screening assessments.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3