Effects of Osseodensification on Primary Stability of Cylindrical and Conical Implants—An Ex Vivo Study

Author:

de Carvalho Formiga Márcio12ORCID,da Silva Helio Doyle Pereira2,Ghiraldini Bruna3,Siroma Rafael Shinoske2,Ardelean Lavinia Cosmina4ORCID,Piattelli Adriano5,Shibli Jamil Awad2ORCID

Affiliation:

1. Department of Periodontology and Oral Implantology, Unisul, Palhoça, 515 Felipe Schmidt Str., Florianopolis 88101-001, SC, Brazil

2. Department of Periodontology and Oral Implantology, Dental Research Division, Guarulhos University, 88 Praça Tereza Cristina Sq., Guarulhos 07011-010, SC, Brazil

3. Dental Research Division, Paulista University, 303 Borges de Figueiredo Str., São Paulo 03110-010, SP, Brazil

4. Department of Technology of Materials and Devices in Dental Medicine, Faculty of Dental Medicine, Multidisciplinary Center for Research, Evaluation, Diagnosis and Therapies in Oral Medicine, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania

5. Department of Medical, Oral and Biotechnological Sciences, University “G. D’Annunzio” of Chieti-Pescara, 332 Viale Abruzzo Str., 66100 Chieti, Italy

Abstract

Primary stability is an important factor for dental implant success. In the past years, a new method for bone site preparation was introduced, named osseodensification (OD). OD produces a condensation of the trabecular portion of the bone, increasing bone-to-implant contact and primary stability. This study aims to compare the effect of OD in cylindrical and conical implants to conventional instrumentation. A total of forty implants, divided into four groups, were placed in porcine tibia: cylindrical conventional (1a), cylindrical OD (1b), conical conventional (2a) and conical OD (2b). Each implant was measured for implant stability quotient (ISQ), insertion torque (IT) and removal torque (RT). Group 2b showed the higher values for each of the evaluated parameters; groups 1b and 2b showed better results than 1a and 2a, respectively. Regarding the IT and RT, group 1b achieved higher values than group 2a, but not for ISQ. The inter-group comparison showed significant difference between groups 1a vs 2a, 1a vs 2b and 1b vs 2b for ISQ and 1a vs 1b and 1a vs 2b for RT analysis. OD resulted in improved ISQ, IT and RT of both cylindrical and conical implants.

Publisher

MDPI AG

Subject

General Medicine

Reference69 articles.

1. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw;Adell;Int. J. Oral Surg.,1981

2. Osseointegrated implants for single-tooth replacement: A prospective 5-year multicenter study;Henry;Int. J. Oral Maxillofac. Implant.,1996

3. Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions;Buser;Periodontol. 2000,2017

4. Effects of titanium surface topography on bone integration: A systematic review;Wennerberg;Clin. Oral Implant. Res.,2009

5. Osseointegration: Hierarchical designing encompassing the macrometer, micrometer, and nanometer length scales;Coelho;Dent. Mater.,2015