Systematic Review on S-ICD Lead Extraction

Author:

Vio Riccardo1ORCID,Forlin Enrico12,Čulić Viktor34ORCID,Themistoclakis Sakis1,Proietti Riccardo5,China Paolo1

Affiliation:

1. Department of Cardiothoracic, Vascular Medicine and Intensive Care, Dell’Angelo Hospital, 30174 Mestre-Venice, Italy

2. Department of Cardiac, Thoracic and Vascular Sciences and Public Health, University of Padua, 35128 Padua, Italy

3. School of Medicine, University of Split, 21000 Split, Croatia

4. Department of Cardiology and Angiology, University Hospital Centre Split, 21000 Split, Croatia

5. Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart and Chest Hospital, Liverpool L8 7TX, UK

Abstract

Background and purpose: Subcutaneous implantable cardioverter defibrillators (S-ICDs) have emerged in recent years as a valid alternative to traditional transvenous ICDs (TV-ICDs). Therefore, the number of S-ICD implantations is rising, leading to a consequent increase in S-ICD-related complications sometimes requiring complete device removal. Thus, the aim of this systematic review is to gather all the available literature on S-ICD lead extraction (SLE), with particular reference to the type of indication, techniques, complications and success rate. Methods: Studies were identified by searching electronic databases (Medline via PubMed, Scopus and Web of Science) from inception to 21 November 2022. The search strategy adopted was developed using the following key words: subcutaneous, S-ICD, defibrillator, ICD, extraction, explantation. Studies were included if they met both of the following criteria: (1) inclusion of patients with S-ICD; (2) inclusion of patients who underwent SLE. Results: Our literature search identified 238 references. Based on the abstract evaluation, 38 of these citations were considered potentially eligible for inclusion, and their full texts were analyzed. We excluded 8 of these studies because no SLE was performed. Eventually, 30 studies were included, with 207 patients who underwent SLE. Overall, the majority of SLEs were performed for non-infective causes (59.90%). Infection of the device (affecting either the lead or the pocket) was the cause of SLE in 38.65% of cases. Indication data were not available in 3/207 cases. The mean dwelling time was 14 months. SLEs were performed using manual traction or with the aid of a tool designed for transvenous lead extraction (TLE), including either a rotational or non-powered mechanical dilator sheath. Conclusions: SLE is performed mainly for non-infective causes. Techniques vary greatly across different studies. Dedicated tools for SLE might be developed in the future and standard approaches should be defined. In the meantime, authors are encouraged to share their experience and data to further refine the existing variegated approaches.

Publisher

MDPI AG

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3