Author:
Wang Hai,Hu Yanxin,Peng Jinqing,Song Mengjie,Li Haoteng
Abstract
The objective of the study is to investigate and optimize the solar flux uniformity of a fixed linear-focus Fresnel lens solar concentrator using a triangle cavity receiver. The effects of receiver parameters including the vertical distance from the cavity opening plane to the Fresnel lens f, receiver internal surface absorptivity αab, end reflection plane reflectivity ρr, solar declination angle δ and solar angle ω on the uniformity factor (UF) of a triangle cavity receiver were carried out. The effects of receiver parameters are evaluated with a significance test of critical factors. The results showed that the increase in f and δ would result in an increase in the UF. The average UF with f = 600, 625, 650, 675 and 700 mm, respectively, are 0.5030, 0.5858, 0.6337, 0.6576 and 0.6784 for ω in range of 0–60°. Moreover, the UF increases as αab decreases when other receiver parameters are constant for the δ of 0–8°. The ρr has a limited effect on the UF until δ becomes relatively larger and ω becomes relatively smaller. Furthermore, ω effects are most significant on the UF, followed by δ, f and αab. Setting a suitable f is the most economical and effective way to improve the UF.
Funder
Guangdong Basic and Applied Basic Research Foundation
Subject
Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献