Complications and Outcomes in 39,864 Patients Receiving Standard Care Plus Mechanical Circulatory Support or Standard Care Alone for Infarct-Associated Cardiogenic Shock

Author:

Padberg Jan-Sören1ORCID,Feld Jannik2ORCID,Padberg Leonie1,Köppe Jeanette2ORCID,Makowski Lena1ORCID,Gerß Joachim2ORCID,Dröge Patrik3ORCID,Ruhnke Thomas3,Günster Christian3ORCID,Lange Stefan Andreas1,Reinecke Holger1

Affiliation:

1. Department for Cardiology I: Coronary and Peripheral Vascular Disease, Heart Failure, University Hospital Münster, Albert-Schweitzer-Campus 1, D-48149 Münster, Germany

2. Institute of Biostatistics and Clinical Research, University of Münster, D-48149 Münster, Germany

3. AOK Research Institute (WIdO), AOK-Bundesverband, D-10178 Berlin, Germany

Abstract

Background: Temporary mechanical circulatory support devices (tMCS) are increasingly being used in patients with infarct-associated cardiogenic shock (AMICS). Evidence on patient selection, complications and long-term outcomes is lacking. We aim to investigate differences in clinical characteristics, complications and outcomes between patients receiving no tMCS or either intra-aortic balloon pump (IABP), veno-arterial extracorporeal membrane oxygenation (V-A ECMO) or Impella® for AMICS, with a particular focus on long-term outcomes. Methods: Using health claim data from AOK—Die Gesundheitskasse (local health care funds), we retrospectively analysed complications and outcomes of all insured patients with AMICS between 1 January 2010 and 31 December 2017. Results: A total of 39,864 patients were included (IABP 5451; Impella 776; V-A ECMO 833; no tMCS 32,804). In-hospital complications, including renal failure requiring dialysis (50.3% V-A ECMO vs. 30.5% Impella vs. 29.2 IABP vs. 12.1% no tMCS), major bleeding (38.1% vs. 20.9% vs. 18.0% vs. 9.3%) and sepsis (22.5% vs. 15.9% vs. 13.9% vs. 9.3%) were more common in V-A ECMO patients. In a multivariate analysis, the use of both V-A ECMO (HR 1.57, p < 0.001) and Impella (HR 1.25, p < 0.001) were independently associated with long-term mortality, whereas use of IABP was not (HR 0.89, p < 0.001). Kaplan–Meier estimates showed better survival for patients on IABP compared with Impella, V-A ECMO and no-tMCS. Short- and long-term mortality was high across all groups. Conclusions: Our data show noticeably more in-hospital complications in patients on tMCS and higher mortality with V-A ECMO and Impella. The use of both devices is an independent risk factor for mortality, whereas the use of IABP is associated with a survival benefit.

Funder

Federal Joint Committee, Innovation Committee

Open Access Publication Fund of the University of Münster

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Unloading in cardiogenic shock: the rationale and current evidence;Current Opinion in Critical Care;2024-05-27

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3