A Comparison of Miller Straight Blade and Macintosh Blade Laryngoscopes for Intubation in Morbidly Obese Patients

Author:

Ratajczyk Pawel1,Kluj Przemysław1ORCID,Szmyd Bartosz2,Resch Julia1,Hogendorf Piotr3,Durczynski Adam3,Gaszynski Tomasz1ORCID

Affiliation:

1. Department of Anaesthesiology and Intensive Therapy, Medical University of Lodz, 90-419 Lodz, Poland

2. Department of Neurosurgery and Neuro-Oncology, Medical University of Lodz, 90-419 Lodz, Poland

3. Department of General and Transplant Surgery, Medical University of Lodz, 90-419 Lodz, Poland

Abstract

The primary objective of this study was to demonstrate whether the Miller blade laryngoscope could provide better visualization of the vocal cords in morbidly obese patients than the Macintosh blade laryngoscope. The secondary objective was to identify the patient-measured factors associated with better visualization of the vocal cords when using the Miller vs. Macintosh blade, as well as whether the application of external pressure might improve the visibility of the glottis during intubation. A prospective, observational study encompassing 110 patients with a BMI > 40 undergoing elective bariatric surgery and intubation procedure was performed. The evaluation of the vocal cords was performed according to the Cormack–Lehane scale and POGO scale in the same patient during intubation, performed with a Miller and a Macintosh blade laryngoscope, in a random matter. The following parameters were assessed: body weight, height, BMI, neck circumference, thyromental distance, sternomental distance, mouth opening, and Mallampati scale and their impact on visualization of the vocal cords using the Miller blade without the application of external pressure. The Miller blade provides an improved view of the glottis compared to the Macintosh blade measured with both the Cormac–Lehane scale (45 (40.91%) without external pressure application on the larynx, and 18 (16.36%) with external pressure application on the larynx) and the POGO scale (45 (40.91%) without external pressure application on the larynx, and 19 (17.27%) with external pressure application on the larynx). The application of laryngeal pressure improved the view of the glottis. Among the measured features, a significant improvement in the visibility of the glottis could be found in patients with a BMI over 44.244 kg/m2 and a neck circumference over 46 cm. To conclude, the usage of the Miller blade improves the visibility of the glottis compared to the Macintosh blade in morbidly obese patients. The recommendation to use the Miller blade in this group of patients requires further investigation, taking into account the effectiveness of the intubation. Trial Registration: NCT05494463.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3