The Atlas of the Inferior Mesenteric Artery and Vein under Maximum-Intensity Projection and Three-Dimensional Reconstruction View

Author:

Zhang Hongwei1,Liu Shurong1,Dong Bingqi1ORCID,Liu Jing2,Guo Xiaochao2,Chen Guowei1,Jiang Yong1,Wu Yingchao1,Zhang Junling1,Wang Xin1

Affiliation:

1. Department of Gastrointestinal Surgery, Peking University First Hospital, Beijing 100034, China

2. Department of Radiology, Peking University First Hospital, Beijing 100034, China

Abstract

(1) Background: Understanding vascular patterns is crucial for minimizing bleeding and operating time in colorectal surgeries. This study aimed to develop an anatomical atlas of the inferior mesenteric artery (IMA) and vein (IMV). (2) Methods: A total of 521 patients with left-sided colorectal cancer were included. IMA and IMV patterns were identified using maximum-intensity projection (MIP) and three-dimensional (3D) reconstruction techniques. The accuracy of these techniques was assessed by comparing them with surgical videos. We compared the amount of bleeding and operating time for IMA ligation across different IMA types. (3) Results: Most patients (45.7%) were classified as type I IMA, followed by type II (20.7%), type III (22.6%), and type IV (3.5%). Newly identified type V and type VI patterns were found in 6.5% and 1% of patients, respectively. Of the IMVs, 49.9% drained into the superior mesenteric vein (SMV), 38.4% drained into the splenic vein (SPV), 9.4% drained into the SMV–SPV junction, and only 2.3% drained into the first jejunal vein (J1V). Above the root of the left colic artery (LCA), 13.1% of IMVs had no branches, 50.1% had one, 30.1% had two, and 6.7% had three or more branches. Two patients had two main IMV branches, and ten had IMVs at the edge of the mesocolon with small branches. At the IMA root, 37.2% of LCAs overlapped with the IMV, with 34.0% being lateral, 16.9% distal, 8.7% medial, and both the marginal type of IMV and the persistent descending mesocolon (PDM) type represented 1.4%. MIP had an accuracy of 98.43%, and 3D reconstruction had an accuracy of 100%. Blood loss and operating time were significantly higher in the complex group compared to the simple group for IMA ligation (p < 0.001). (4) Conclusions: A comprehensive anatomical atlas of the IMA and IMV was provided. Complex IMA patterns were associated with increased bleeding and operating time.

Funder

National Key R&D Program of China

National Natural Science Foundation of China

Youth Clinical Research Project of Peking University First Hospital

Scientific Research Seed Fund of Peking University First Hospital

Youth Cultivated Research Fund of Peking University Health Center

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3