Finite Element Analysis (FEA) of the Stress and Strain Distribution in Cone-Morse Implant–Abutment Connection Implants Placed Equicrestally and Subcrestally

Author:

Di Pietro Natalia12ORCID,Ceddia Mario3,Romasco Tea12ORCID,De Bortoli Junior Nilton4,Mello Bruno Freitas5,Tumedei Margherita6,Specchiulli Alessandro1,Piattelli Adriano78,Trentadue Bartolomeo3ORCID

Affiliation:

1. Department of Medical, Oral and Biotechnological Sciences, “G. d’Annunzio” University of Chieti-Pescara, 66100 Chieti, Italy

2. Center for Advanced Studies and Technologies (CAST), “G. d’Annunzio” University of Chieti-Pescara, 66100 Chieti, Italy

3. Department of Mechanics, Mathematics and Management, Politecnico di Bari University, 70125 Bari, Italy

4. Department of Oral Implantology, Associação Paulista dos Cirurgiões Dentistas—APCD, São Bernardo do Campo 02011-000, Brazil

5. Department of Periodontology and Oral Implantology, Unisul University, Florianopolis 88101-001, Brazil

6. Department of Medical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy

7. School of Dentistry, Saint Camillus International University of Health and Medical Sciences, 00131 Rome, Italy

8. Facultad de Medicina, UCAM Universidad Católica San Antonio de Murcia, 30107 Murcia, Spain

Abstract

Peri-implant bone resorption has been reported around some implants after loading, which could create problems for the peri-implant soft and hard tissues’ long-term stability. The reasons for this are still not known. However, relevant importance could be given to this due to the presence of a bacterial contamination at the micro-gap level between implant and abutment. In this regard, external and internal implant–abutment assemblies have been shown to be much more permeable to bacterial colonization than Cone-Morse or conical connections. The placement of a subcrestal implant could have aesthetic advantages, therefore allowing a better prosthetic emergence profile. In literature, controversial experimental and clinical results have been reported on bone resorption around implants placed equicrestally and subcrestally. Interestingly, Finite Element Analysis (FEA) studies revealed to be extremely useful for assessing the peri-implant bone strain and stress. Thus, this study conducted a FEA evaluation of implants with a Cone-Morse implant–abutment assembly inserted into a bone block model mimicking equicrestal (0 mm) and subcrestal placements (−1 and −2 mm). Results demonstrated that maximum stresses were observed in the cortical bone around equicrestally placed implants, with the lowest in the 2 mm subcrestally placed implant and intermediate stresses within the 1 mm subcrestally placed implant. The cortical bone resulted more stressed under lateral loads than axial loads. In conclusion, this FEA study suggested a subcrestal implant placement ranging between −1 and −2 mm to obtain an adequate peri-implant stress pattern.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3