Affiliation:
1. School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
2. MOE Key Laboratory of Cryogenic Technology and Equipment, Xi’an Jiaotong University, Xi’an 710049, China
Abstract
With the rapid development of information technology, researchers have paid attention to the pump-driven two-phase cooling loop technology for data centers, which imposes requirements on the efficiency and size of the pump. A fluid self-lubricating centrifugal pump with R134a refrigerant was developed to reach a higher rotation speed and oil-free system, resulting in a more diminutive size. Due to the high rotation speed and refrigerant pressure approaching saturated vapor pressure, the internal flow characteristics and cavitating characteristics are critical and complex. This paper focuses on the prototype’s head and cavitation performance based on experimental and numerical data. The experiments indicated that the head coefficient of the pump under design conditions is 0.9881, and the pump’s critical cavitation number and breakdown number are 0.551 and 0.412, respectively. The numerical results can predict the head and cavitation with deviations less than 2.6%. To study changing patterns in flow characteristics under the different operating conditions in the refrigerant centrifugal pump, the numerical model based on a modified Sauer-Schnerr cavitation model was built to analyze the distributions of pressure, temperature, relative velocity, and bubble volume across every hydraulic component and different degrees of cavitation, and proposed the influence of the thermal effect on refrigerant cavitating. The cavitating flow characteristics were obtained with the aim of providing guidance for the hydraulic design of a refrigerant centrifugal pump.
Funder
China Postdoctoral Science Foundation
Youth Innovation Team of Shaanxi Universities
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Reference39 articles.
1. On-Chip Two-Phase Cooling of Datacenters: Cooling System and Energy Recovery Evaluation;Marcinichen;Appl. Therm. Eng.,2012
2. Development and Analysis of a Pump-Driven Loop Heat Pipe Unit for Cooling a Small Data Center;Zhou;Appl. Therm. Eng.,2017
3. Flow Boiling Heat Transfer Mechanisms and Flow Characteristics of Pump-Driven Two-Phase Flow Systems Used in Data Center Cooling;Chen;Appl. Therm. Eng.,2023
4. An Advanced Microturbine System with Water-Lubricated Bearings;Nakano;Int. J. Rotating Mach.,2009
5. Yuan, X., Zhang, G., Zhao, W., Li, Z., and Yang, S. (2008). International Joint Tribology Conference, American Society of Mechanical Engineers Digital Collection.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献