Optimal Use of Titanium Dioxide Colourant to Enable Water Surfaces to Be Measured by Kinect Sensors

Author:

Nichols Andrew,Rubinato MatteoORCID,Cho Yun-HangORCID,Wu Jiayi

Abstract

Recent studies have sought to use Microsoft Kinect sensors to measure water surface shape in steady flows or transient flow processes. They have typically employed a white colourant, usually titanium dioxide (TiO2), in order to make the surface opaque and visible to the infrared-based sensors. However, the ability of Kinect Version 1 (KV1) and Kinect Version 2 (KV2) sensors to measure the deformation of ostensibly smooth reflective surfaces has never been compared, with most previous studies using a V1 sensor with no justification. Furthermore, the TiO2 has so far been used liberally and indeterminately, with no consideration as to the type of TiO2 to use, the optimal proportion to use or the effect it may have on the very fluid properties being measured. This paper examines the use of anatase TiO2 with two generations of the Microsoft Kinect sensor. Assessing their performance for an ideal flat surface, it is shown that surface data obtained using the V2 sensor is substantially more reliable. Further, the minimum quantity of colourant to enable reliable surface recognition is discovered (0.01% by mass). A stability test shows that the colourant has a strong tendency to settle over time, meaning the fluid must remain well mixed, having serious implications for studies with low Reynolds number or transient processes such as dam breaks. Furthermore, the effect of TiO2 concentration on fluid properties is examined. It is shown that previous studies using concentrations in excess of 1% may have significantly affected the viscosity and surface tension, and thus the surface behaviour being measured. It is therefore recommended that future studies employ the V2 sensor with an anatase TiO2 concentration of 0.01%, and that the effects of TiO2 on the fluid properties are properly quantified before any TiO2-Kinect-derived dataset can be of practical use, for example, in validation of numerical models or in physical models of hydrodynamic processes.

Funder

Engineering and Physical Sciences Research Council

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3