The evaluation of the radiation dose (RD) deposited by atmospheric neutrons in human tissues is of vital importance due to the potential damages that over exposure to this radiation may cause to human health. The goal of this work was to obtain the RD that atmospheric neutrons with energy from 1 to 1000 MeV deposit in tissues of the human body (blood, adipose, bone and brain) as a function of both altitude and latitude. With the help of the Geant4 software, we developed a numerical simulation that allowed us to reach our goal; atmospheric neutron fluxes were obtained from the Excel-Based Program for Calculating Atmospheric Cosmic-Ray Spectrum (EXPACS). We found that the RD deposited by atmospheric neutrons increases with the increase in altitude and latitude, e.g., for an altitude of high mountain (4 km), the RD is increased ∼19 times; while, for an altitude of commercial flights (10 km), the RD is increased ∼156 times; in both cases, regarding the RD at sea level. We also found that, in the range of energies from 1 to 100 MeV, the RD deposited in the bone tissue sample is considerably lower that the RD deposited in the blood, adipose and brain tissue samples. On the other hand, for the range of energies between 200 and 1000 MeV, the RD deposited in the bone tissue sample is considerably greater that the RD deposited in the blood, adipose and brain tissue samples.