Abstract
In this paper, argon was used in radio frequency (13.56 MHz) dielectric barrier discharge (rf-DBD) at atmospheric pressure. The IV curve was recorded after gas breakdown, and discharge photos were captured by ICCD camera. Discharges of α mode and γ mode were observed based on IV curve and ICCD photos. As the existence of negative glow in γ mode, the luminescence intensity of different position of the discharge gap was analyzed. It was found that in the α mode, the electron avalanche occurs from negative to positive and negative glow appeared after the discharge changed into γ mode. In every half cycle, the peak position of negative glow is 13 ± 1 ns later than that of electron avalanche on cathode surface.
Funder
Shanghai Municipal Education Commission
Shanghai Education Development Foundation
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
4 articles.